AR-5520 SIMULATIONS 7-4
2
10
RSPF paper exit gate solenoid
operation check
(Only when the SPF/RSPF is
installed)
The RSPF paper exit gate solenoid (GSOL) is turned ON for 500msec and OFF for 500msec.
This operation is repeated 20 times.
After completion of the process, the machine goes to the sub code input standby mode.
W
hen the [Interrupt] key is pressed during the process, the machine goes to the sub code input
standby mode.
W
hen the [CA] key is pressed, the simulation is terminated.
11
SPF PS release solenoid operation
check
The SPF PS release solenoid (CLH) is turned ON for 500msec and OFF for 500msec. This operation
is repeated 20 times.
After completion of the process, the machine goes to the sub code input standby mode.
W
hen the
[Interrupt] key is pressed during the process, the machine goes to the sub code input standby mode.
W
hen the [CA] key is pressed, the simulation is terminated.
05
01
Operation panel display check
<<LED check mode (ALL ON/Individual ON)>>
W
hen the [START] key is pressed in the sub code input mode, all the LED's (including the 7-seg
display) are turned ON. After 5 sec of all ON, the machine goes to the sub code input standby mode.
W
hen the [AUTO/TEXT/PHOTO] key is pressed during all ON, the lighting mode is shifted to the
individual ON mode, where the LED's are individually lighted from the left top, to the left bottom, to
the next line top, to the bottom, and so on. (For the 7-seg display, the 3-digit lamps are lighted at
once.)
After completion of lighting of all the lamps, the mode is shifted to the all ON mode.
After 5 sec of all ON mode, the machine goes to the sub code input standby mode.
W
hen the [Interrupt] key is pressed in the LCD check mode, the machine goes back to the sub code
input standby mode.
W
hen the [CA] key is pressed, the simulation is terminated.
W
hen the [START] key is pressed with all the lamps ON, the machine goes back to the key input
check mode.
<< Key input check mode>>
W
hen the machine goes into the key input check mode, [- - -] is displayed on the copy quantity
display. Every time when a key on the operation panel is pressed, the input value is added on the
copy quantity display.
[- - -]
[ 1]
[ 2]
•••.
W
hen a key is pressed once, it is not counted again.
W
hen the [START] key is pressed, the input number is added and displayed for 3 sec, and the
machine goes into the LED lighting check mode (LED all ON state).
W
hen the [Interrupt] key is
pressed for the first time, it is counted.
W
hen the key is pressed for the second time, the machine
goes into the sub code input mode.
W
hen the [CA] key is pressed for the first time, it is counted.
W
hen the key is pressed for the second time, the simulation is terminated. (Note for the key input
check mode).
•Press the [START] key at the end. (
W
hen the key is pressed during the process, the machine goes
into the LED lighting check mode (all ON state).).
•
W
hen two or more keys are pressed simultaneously, they are ignored.
02
Fusing lamp and cooling fan
operation check
W
hen the [START] key is pressed, the fusing lamp turns ON for 500ms and OFF for 500ms.
The operation is repeated 5 times. During this process, the cooling fan motor rotates.
After completion of the process, the machine goes into the sub code input standby mode.
03
Copy lamp lighting check
W
hen the [START] key is pressed, the copy lamp lights up for 5 sec. After completion of lighting, the
machine goes into the sub code input mode.
W
hen the [Interrupt] key is pressed, the process is interrupted and the machine goes into the sub
code input standby mode.
W
hen the [CA] key is pressed, the simulation is terminated.
Main
code
Sub
code
Contents
Details of operation
Individual ON mode cycle:
300ms for ON
20ms for OFF
Содержание AR-5516