AR-5520 SIMULATIONS 7-7
22
07
Mini maintenance preset display
(Valid only when the destination is
set to Japan AB series)
The mini maintenance cycle data is acquired and displayed on the 7-seg display.
W
hen the [Interrupt] key is pressed, the machine goes into the sub code input standby mode.
W
hen the [CA] key is pressed, the simulation is terminated.
08
SPF counter display
The SPF counter value is displayed.
09
Paper feed counter display
The counter value of the selected paper feed section is acquired from each variable, the data is
displayed on the 7-seg display according to the regulations.
W
hen this simulation is executed, the
value of the 1st paper tray is displayed first. Press the [TRAY SETTING] key to select the tray.
W
hen
the [Interrupt] key is pressed, the machine goes into the sub code input standby mode.
W
hen the [CA] key is pressed, the simulation is terminated.
12
Drum counter display
The drum counter and the drum rotating time are displayed.
To change the display mode, press the [AUTO/TEXT/PHOTO] key.
13
CRUM destination display
W
hen this simulation is executed, the CRUM destination set (written) in the CRUM chip is displayed.
This simulation is valid only for the models where the CRUM is valid.
14
P-ROM version display
The P-ROM version is displayed on the copy quantity display. The main code and the sub code are
alternatively displayed by 2 digits. The display interval is same as that of the counter display.
By pressing the fixed [PRESET RATIO selector] keys, each version display is switched.
15
Trouble memory display
The trouble codes up to the latest one are acquired from the trouble memory data.
Every time when the magnification ratio display is pressed, the main code of the trouble is displayed
on the 1st ~ 2nd digit.
*
The latest 20 troubles are stored in the memory.
The 3rd digit indicates the trouble history code, "A" ~ "J" (meaning of 1 ~ 10).
After "J" is displayed, "A" ~ "J" blinks. (Meaning of 11 ~ 20)
After "J" blinks (meaning of 20), "A" ~ "J" is lighted. (Returns to 1.)
W
hen the [START] key is pressed, the sub code is displayed.
W
hen the [Interrupt] key is pressed, the machine goes into the sub code input standby mode.
W
hen the [CA] key is pressed, the simulation is terminated.
*
Note that when the history code blinks, the trouble code and the sub code do not blink.
16
Duplex print counter display
(Duplex model only)
Data is acquired from the duplex print counter variable, and is displayed.
W
hen the [Interrupt] key is pressed, the machine goes into the sub code input standby mode.
W
hen the [CA] key is pressed, the simulation is terminated.
17
Copy counter display
The copy counter value is displayed.
W
hen the [Interrupt] key is pressed, the machine goes into the
sub code input standby mode.
W
hen the [CA] key is pressed, the simulation is terminated.
18
Printer counter display
The printer counter value is displayed.
W
hen the [Interrupt] key is pressed, the machine goes into the
sub code input standby mode.
W
hen the [CA] key is pressed, the simulation is terminated.
19
Scanner mode counter display
(Except for AR-5516S/AR-5520S)
The scanner mode counter value is displayed.
W
hen the [Interrupt] key is pressed, the machine goes
into the sub code input standby mode.
W
hen the [CA] key is pressed, the simulation is terminated.
21
Scanner counter display
The scanner counter value is displayed.
W
hen the [Interrupt] key is pressed, the machine goes into
the sub code input standby mode.
W
hen the [CA] key is pressed, the simulation is terminated.
22
SPF jam counter display
(Only when the SPF/RSPF is
installed)
The SPF jam counter value is displayed.
W
hen the [Interrupt] key is pressed, the machine goes into
the sub code input standby mode.
W
hen the [CA] key is pressed, the simulation is terminated.
50
Developer rotation time display
The developer rotation time is displayed. (Three digits are displayed alternatively.)
W
hen [Interrupt] key is pressed, the display goes to the sub code input standby state.
W
hen [CA] key
is pressed, the machine goes out of the simulation mode.
51
Drum rotation time display
The drum rotation time is displayed. (Three digits are displayed alternatively.)
W
hen [Interrupt] key is pressed, the display goes to the sub code input standby state.
W
hen [CA] key
is pressed, the machine goes out of the simulation mode.
Main
code
Sub
code
Contents
Details of operation
LED
Display mode
AUTO exposure indicator
TEXT indicator
Drum counter
Drum rotating time
7-seg display
Meaning (CRUM destination)
7-seg display
Meaning (CRUM destination)
00
01
02
03
Not set yet
BTA-A
BTA-B
BTA-C
04
05
06
99
CHN-A
JPN_A
BTA_F
Conversion
LED (AB series)
LED (Inch series)
Displayed version
141%