AR-203E/5420/M200/M201 SIMULATION, TROUBLE CODES 10 - 5
05
01
Operation panel display
check
[Function]
<LED check mode (All ON/Individual ON)>
When [OK]/[ENTER]/[START] key is pressed, all the LCD's on the operation panel are turned
ON (all pixels ON).
After 5sec of ON, the machine goes into the sub code entry standby mode.
When [Mode Select] key is pressed under the all ON state, the mode is shifted to the individual
ON mode, where the LED's are turned on one by one from the left upper end to the left lower
side then from the right upper side to the right lower side. (All the pixels of LCD are lighted
simultaneously.) After lighting all the LCD's sequentially, all the LCD's are lighted simulta-
neously. After 5sec from lighting all the LCD's simultaneously, the machine goes into the sub
code entry standby mode. (Cycle of individual ON mode: ON 300ms, OFF 20ms)
When [Clear] key is pressed in the LED check mode, the machine goes into the sub code entry
standby mode.
When [START] key is pressed, the machine goes into the key input check mode.
<Key input check mode>
When the machine goes into the key input check mode, the value display section indicates "– –
–" (For the AR-M200/M201, 0 of the LCD is indicated).
When any key is pressed after pressing a key on the operation panel, "+1" is added to the
value.
Once a key is pressed, it is not recounted.
When [START] key is pressed, counting is made and the machine goes into the LED ON check
mode (LED all ON status) after 3sec.
When [Clear] key is pressed for the first time, it is counted. When it is pressed for the second
time, the key check mode is retained as well as when another key is pressed.
(Note in the key input check mode)
• Be sure to press [START] key at the last. (If it is pressed on the way, the machine goes into
the LED ON check mode.) (LED all ON status)
• Multi key input is ignored.
[Operation] (AR-M200/M201)
<LED check mode (All ON/Individual ON)>
<Key input check mode>
02
Fusing lamp, cooling fan
operation check
[Function]
When [OK]/[ENTER]/[START] key is pressed, the fusing lamp repeats ON for 500ms and OFF
for 500ms 5 times. During this period, the cooling fan motor rotates.
Note:
When the CE mark setting is ON, the slow start function may operate depending on the
employed frequency. If the state of the heater lamp cannot be checked, temporarily set SIM 26-
30 to "0" and check the lamp state. After confirming that the heater lamp is ON, set SIM 26-30
to "1" again.
[Operation] (AR-M200/M201)
03
Copy lamp ON
[Function]
When [OK]/[ENTER]/[START] key is pressed, the copy lamp turns ON for 5sec.
[Operation] (AR-M200/M201)
Main
code
Sub
code
Contents
Details of function/operation
1) Initial
display
2) When [Mode Select] key is pressed, the machine goes into the individual ON mode.
■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■
1) Initial display
2) [OK]/[ENTER]/[START]
key
05-01 LCD/LED CHK.
0
05-01 LCD/LED CHK.
**
1) Initial display
05-02 HT LAMP CHK
EXECUTING...
1) Initial display
05-03 C-LAMP CHK
EXECUTING...
Содержание AR-203E X
Страница 172: ...Memo ...
Страница 173: ...Memo ...