AR-203E/5420/M200/M201 SIMULATION, TROUBLE CODES 10 - 17
41
06
OC cover float detection
level adjustment (Only the
AR-203E/M200/M201 with
the SPF/RSPF installed)
[Function]
When this simulation is executed, the current set value is displayed. When [OK]/[ENTER]/
[START] key is pressed, the mirror base unit moves to the SPF/RSPF scan position to acquire
the OC cover float detection level.
When the mirror base unit returns to the home position, the acquired value is displayed.
If the adjustment is NG, the following message is displayed.
AR-203E/5420: Misfeed lamp lights up, and the 7seg display remains unchanged.
AR-M200/M201: The LCD indicates "ERR."
Note that, this simulation must be executed with the OC cover closed.
∗
If the value is 0, float detection is not performed in normal jobs.
[Operation] (AR-M200/M201)
07
OC cover float detection
margin setting (Only the
AR-203E/M200/M201 with
the SPF/RSPF installed)
[Function]
For the number of pixels between black markers on the SPF/RSFP scanning position saved in
"41-06: (OC cover float detection level adjustment)", if the number of pixels between the mark-
ers when processing float detection is less than the number of pixels set with this simulation, it
is judged as the float error.
When the set value of this simulation is "0," no float error occurs.
When this simulation is executed, the current set value is displayed.
Enter the adjustment value with [ ] [ ] key
(or [Numeric] key for the AR-M200/M201), and press
[START] key. The setting is saved and the display is shifted to the sub code input standby menu.
Setting range: 0 – 99 (Copes with margin 0 – 99 pixels.)
Default: 30 (30 pixels)
[Operation]
The operation is similar to simulation 09-04.
43
01
Fusing temperature setting
(Normal copy)
[Function]
Used to set the fusing temperature of 3rd or later sheet. (For 1st and 2nd sheets, simulation 43-
14 is used.)
When this simulation is executed, the current set code number is displayed. Press [ ] [ ] key
(or [Numeric] key for the AR-M200/M201) to change the setting and press [OK]/[ENTER]/
[START] key to save the setting into the EERPOM. The machine goes into the sub code entry
standby mode.
The [Exposure mode selector] key (or [
] [
] key for the AR-M200/M201) is used to select
the mode.
[Operation]
Main
code
Sub
code
Contents
Details of function/operation
1) Initial display
2) [OK]/[ENTER]/[START]
key
41-06 OC FLOAT LEVEL
0
41-06 OC FLOAT LEVEL
EXECUTING...
<Canceling - when [Clear]/[Clear All] key is pressed->
After canceling, the machine goes into the sub code entry
standby mode.
3) When the level is
acquired:
3) When the level is not
acquired:
THE JOB IS BEING
CANCELED.
41-06 OC FLOAT LEVEL
**** OK
41-06 OC FLOAT LEVEL
**** ERR
* The cassette feed and the manual feed are controlled similarly.
Code
Set temperature (°C)
Remark
Code
Set temperature (°C)
Remark
0
170
5
195
Default
1
175
6
200
2
180
7
205
3
185
8
210
4
190
Mode
Display item
(AR-M200/M201)
Display item
(AR-203E/5420)
Main cassette paper feed & 2nd cassette paper feed
TRAY1
AE mode lamp
Manual paper feed
MFT
TEXT mode lamp
AR-M200/M201
1) Initial display <Main cassette paper feed
& 2nd cassette paper feed setting>
2) [
] [
] key: Mode selection
3) [Numeric] key: Value entry
4) [OK]/[ENTER]/[START] key
Settles the entered value. The display is
shifted to the sub code input standby
menu.
AR-203E/5420
1) Press [Exposure mode selector] key to
change the mode.
2) Press [ ] [ ] key to set the value.
3) Press [START] key to fix the code
number.
43-01 FU TEMP
TRAY1 6( 0-8 )
43-01 FU TEMP
MFT 6( 0-8 )
43-01 FU TEMP
MFT 6( 0-8 )