AR-203E/5420/M200/M201 DISASSEMBLY AND ASSEMBLY 8 - 21
C. DV blade
1) Peel off the old DV blade.
2) Clean the attachment surface with alcohol.
3) Attach the new DV blade to the reference position.
D. DV doctor
1) Remove the screw, and remove the DV doctor.
* Clean the edge (A) section.
■
Note for installation
1) Insert the DG check gauge as shown in the figure.
2) After checking, install the doctor gap and fix it with a screw.
* Apply screw lock to the screw tightening section as shown in the
figure below.
E. DV sensor
1) Remove the Mylar.
2) Remove the screw, and remove the DV sensor.
* Clean the sensor (A) section.
10. Duplex motor section (AR-M201 only)
A. List
B. Disassembly procedure
1) Remove the rear cabinet.
2) Remove two screws.
3) Remove the Duplex motor cover.
4) Remove the Duplex motor.
Note: When reassembling, be sure to engage the Duplex motor
gear with the belt on the main body side.
C. Assembly procedure
For assembly, reverse the disassembly procedure.
B
A
B
A
DV-BOX AS
0.5
0
DV blade IC
1)
2)
A
1)
F/R
secti
on
C
sec
tion
REAR
MG-ROL
DG:1.5
5
0.15
DG:1.5
0.10
FRONT
20
20
10
10
110
F
C
R
* After checking the DG,
apply screw lock.
DG check
gauge
DG check
gauge
DG check
gauge
DG check
gauge
1
2
DG check
position
No.
Part name Ref.
1
Duplex motor
1)
2)
2)
A
3)
1
2
3
1