The followings are descriptions of the ADVANCED SETUP MENU.
Setting Automatic Logout Time (ADVANCED[1]Auto Logout Time)
If there is no input after a fixed time, AN-LS1 automatically disconnects network connection using the
Auto Logout function. It is possible to set the time until AN-LS1 is automatically disconnected in units
of a minute (from 1 to 65535 minutes).
advanced>1
Valid range
: 0 to 65535 (minute)
note: if you enter “0”, auto logout function will be disable.
Auto Logout Time : 5
Please Enter
: 15
(change) —> 15
•
If the set value is made 0, the Auto Logout function is disabled.
COM Redirect Port Setting (ADVANCED[2]COM Redirect Port)
Setting of TCP port number capable of connecting using Sharp COM Redirection Software.
Can be set in the range of 1025 to 65535.
advanced>2
Valid range
:1025 to 65535
COM Redirect Port :10002
Please Enter
:10005
(change) —> 10005
Enter “1” and press the return key.
Enter numerical value and press
the return key.
Display set numerical value.
Enter “2” and press the return key.
Enter numerical value and press
the return key.
Display set numerical value.