ADVANCED SETUP MENU
******************** ADVANCED SETUP MENU ***********************
[1]Auto Logout Time [2]COM Redirect Port [3]Busy Reply
[4]Input Hold Time
[5]Network Ping Test
[6]Accept IP Addr(1) [7]Accept IP Addr(2)
[8]Accept IP Addr(3)
[9]Accept All IP Addr [0]Port for Search
[!]Restore Default Setting
[Q]Return to Main Menu
advanced>
[1]
Auto Logout Time
(Factory default setting : 5 minutes)
Setting of time until automatic disconnection of network connection. (
)
[2]
COM Redirect Port
(Factory default setting : 10002)
Setting of TCP port No. capable of connecting using Sharp COM Redirection Software. (
[3]
Busy Reply
(Factory default setting : ERR + <CR> code)
When separate devices are connected to the two control terminals
(RS-232C (CONTROLLER)
and
10BASE-T)
, it is not possible to use one control terminal while data is being transmitted using
the other control terminal.
This setting is for operation of the control terminal that cannot be used.
(
)
[4]
Input Hold Time
(Factory default setting : 1000 milliseconds)
Changing value for Input Hold Time when a response is not returned from a projector within a set
time while separate devices are connected to the two control terminals
(RS-232C (CONTROLLER)
and
10BASE-T)
[5]
Network Ping Test
It is possible to confirm that a network connection between AN-LS1 and a computer etc. is working
normally. (
[6]
Accept IP Addr(1)
[7]
Accept IP Addr(2)
[8]
Accept IP Addr(3)
[9]
Accept All IP Addr
(Factory default setting : Accept All)
For improved security, it is possible to set up to three IP addresses allowing connection to AN-
LS1. Set IP addresses can be cancelled using [9] Accept All IP Addr. (
[0]
Port for Search
(Factory default setting : 5006)
Setting for port number used when Sharp COM Redirection Software searches for AN-LS1. (
[!]
Restore Default Setting
Restores all setting values that can be set using the menu to the default state.
(
[Q]
Return to Main Menu
Return to the main SETUP MENU. (