User’s guide
HRK 65-125
-
9
-
HS
Safety precautions
4.1
EMERGENCY STOP
There is an emergency stop button (
C
) at the front of the air/timer unit, which can be
reached by the operator from the normal working position.
Pressing the emergency stop button switches off the timer and the top frame lifts up. The
button remains pushed in.
Resetting of the emergency button comes to pass by turning the button to the right.
The machine is ready to use again.
4.2
ONLY USE THE EMERGENCY STOP BUTTON WHEN:
o
Risk of trapped limbs.
o
Defects in the timer, so the machine fails to open after the pre-set time.
o
An outbreak of fire or situations involving a risk of fire.
o
Any situation that might present a risk to people or animals.
o
Any other situation, that might present a risk or cause, damage to the machine
and/or objects.