Oven control devices hidden parameters of the factory is as follows.
Pr.1: 40 ° C (temperature will remain off how much of a turbo under the set
point in the first study)
Pr.2: 9 min (first study period to wait when the turbo is disabled)
Pr.3: -5ºC (Upper hysteresis value)
PR.4: 0ºC (lower hysteresis value)
Pr.5: 40ºC (activating the cooling fan girecig oven temperature)
Pr.6: 1 (Buzzer on or off value. 1 buzzer on)
FAULTS and WARNINGS:
Er.1:
Oven thermocouple (TC) is the open ends of the temperature indicator Er.1
writer. On the other intermittent buzzer and siren relay pull releases. All controls
remain disabled. Failure resolved until the system fails. When the fault corrected
setting must be done again.
Er.2:
Oven temperature rises above the temperature indicator 400ºc'n Er.2 writer.
On the other intermittent buzzer and siren relay pull releases. All controls remain
disabled. Failure resolved until the system fails. When the fault corrected setting
must be done again.
Er.3:
Limit thermostat (LT1) Er.3 writers on the temperature display when the
input signal. On the other intermittent buzzer and siren relay pull releases. All
controls remain disabled. Failure resolved until the system fails. When the fault
corrected setting must be done again.
USING THE DEVICE
18
Содержание MD-1200-1
Страница 1: ......
Страница 2: ...ME 1200 1 MK 1200 D MD 1200 1 ME 1200 2 ...
Страница 7: ...STRAIGHT POWER SCHEME 7 ...
Страница 8: ...STEAM ELECTRIC SCHEME 8 ...
Страница 10: ...PRODUCT LABEL INFORMATION 10 ...
Страница 11: ...PRODUCT LABEL INFORMATION 11 ...
Страница 22: ...22 ...
Страница 23: ...23 ...
Страница 24: ...24 ...
Страница 25: ...25 ...
Страница 26: ...26 ...
Страница 27: ......