background image

37

Product Version 1.0 | Revision A | Released 2022-4-21

PLEASE NOTE! THE LIST BELOW IS SUBJECT TO CHANGE WITHOUT NOTICE.

ORDERING INFORMATION

i-6

i-6

 RGBW, 2.3deg, Std BL 

P/N: 80031700

i-6

 RGBW, 2.3deg, Std, CU 

P/N: 80031702

i-6

 RGBW, 2.3deg, Std, WH 

P/N: 80031701 

i-6

 RGBW, 3.4deg, Std BL 

P/N: 80031720

i-6

 RGBW, 3.4deg, Std, CU 

P/N: 80031722

i-6

 RGBW, 3.4deg, Std, WH 

P/N: 80031721

i-6 White

i-6 W, 2.3deg, Std, BL 

P/N: 80031710 

i-6 POI

i-6

 RGBW, 2.3deg, POI, BL 

P/N: 80251775

i-6

 RGBW, 2.3deg, POI, WH 

P/N: 80251776 

i-6

 RGBW, 2.3deg, POI, CU 

P/N: 80251777

i-6

 RGBW, 3.4deg, POI, CU 

P/N: 80251792

i-6

 RGBW, 3.4deg, POI, WH 

P/N: 80251791

i-6

 RGBW, 3.4deg, POI, BL 

P/N: 80251790

i-6 White POI

I-6 W, 2.3deg, POI, CU 

P/N: 80251782

I-6 W, 2.3deg, POI, WH 

P/N: 80251781

I-6 W, 2.3deg, POI, BL 

P/N: 80251780

i-6 SERIES ACCESSORIES

Omega bracket w/Q-bolt,, BL / WH 

P/N: 83060602 / 83061206

Omega bracket POI with M10 Screws, BL / WH 

P/N: 83060623 / 83060624

USB uploader cable 

P/N: 83062011

USB POI uploader cable 

P/N: 83062067

Half Anti-Glare Shield, BL 

P/N: 83061178

Half Anti-Glare Shield, WH 

P/N: 83061179

Full Anti-Glare Shield, BL 

P/N: 83061176

Full Anti-Glare Shield, WH 

P/N: 83061177

SGM Vacuum test-kit 

P/N: 83061136

FIXTURES AND ACCESSORIES

Содержание i-6

Страница 1: ...USERMANUAL i 6 Product Version 1 0 Document Revision A Released 2022 4 21...

Страница 2: ...s available at www sgmlight com or upon request via support sgmlight com The information in this document is subject to change without notice SGM and all affiliated companies disclaim liability for an...

Страница 3: ...POI All dimensions in millimetres and inches Drawing not to scale 320mm 12 60in 111mm 4 37in 150mm 5 91in 166mm 6 53in 220mm 8 66in 209 172mm 6 78in 326mm 12 82in 401mm 15 77in 468mm 18 41in 81mm 3 19...

Страница 4: ...ter 12 Signal priority 13 INSTALLATION POI FIXTURE 13 Identification and terminology 14 Unpacking 14 Application considerations 14 Connecting temporary Power 14 Connecting temporary signal 15 Settings...

Страница 5: ...ION 28 FIXTURE PROPERTIES 28 Factory default 28 LED Engine 28 Individual fixture settings 30 CONTROL MENU 32 RDM 32 Supported RDM functions 32 Sensors 33 ACCESSORIES 33 Anti glare shields 33 MAINTENAN...

Страница 6: ...from objects to be illuminated Install only in accordance with applicable building codes Ensure a minimum clearance of 0 3 m 12 in around the cooling fans Do not paint cover or modify the device and d...

Страница 7: ...ower and data cable leads are not intended for installation in per manently installed conduit or containment When installing the fixtures in a permanent instal lation ensure cable leads are installed...

Страница 8: ...ice IDENTIFICATION AND TERMINOLOGY B A A 24 LEDs 5 Red 5 Green 5 Blue 9 White B Tilt lock C Cooling fans D Control panel POI n a E OLED Display POI n a F Rubber feet POI n a G GORE TEX membrane H Powe...

Страница 9: ...e ventilation It is not immersed or submerged in water TRANSPORT HANDLING Always use the supplied packaging or suitable flight case for transportation and storage Never carry the fixture by connected...

Страница 10: ...d a lock nut For longer term installations choose outdoor rated hardware 3 Align the omega bracket with the i 6 Series base For standard Omega Bracket insert the fasteners into the i 6 Series base bra...

Страница 11: ...t wing screws one on each side by turning them counter clockwise Tilt the fixture to the angle desired and hold it Lock the position by re tightening both tilt lock screws clock wise CAUTION ALWAYS LE...

Страница 12: ...ed male and female 5 pin XLR plugs For outdoor installa tions use only IP rated XLR connectors suitable for outdoor use Terminate the DMX out cable of the last fixture in the data link with a 120 ohm...

Страница 13: ...cts This is subject to change without notice B A A 24 LEDs 5 Red 5 Green 5 Blue 9 White B Tilt lock C Cooling fans D Rubber feet POI n a E GORE TEX membrane F Power in and out G DMX in and out H LED I...

Страница 14: ...mporary programming a plug or terminals can be used The power cable color coding is shown to the left Connect the black wire to live Connect the white wire to neutral Connect the green yellow wire to...

Страница 15: ...and look for the green light to illuminate on the fixture If the green light does not appear cycle power or refer to troubleshooting STEP 2 Select the standard settings tab and enter a DMX address an...

Страница 16: ...Green Orange Red Fixture is resetting and error s has occurred during reset Blinking Green Red Reset has completed but error s occurred during reset Solid Red 3 seconds Hall sensor is activated When a...

Страница 17: ...talled in any orientation and it might take up to two brackets per fixture Depending on the structure please use appropriate and secure methods for mounting the Omega brackets 159mm 6 26in 106mm 4 17i...

Страница 18: ...ET ATTACHMENT M10 Countersunk Bolts Flat Bracket 8mm or smaller screw or bolt to structure 8mm or smaller screw or bolt to structure 13mm 0 5in hole diameter for attachment point M10 Stainless Steel B...

Страница 19: ...ys use 2 bolts with washers Using a bolt through this slot the fixture will rotate around its center point always use 2 bolts with washers PLEASE NOTE THE UNIVERSAL BRACKET HAS DIFFERENT SLOT CURVES F...

Страница 20: ...n to the surface Using the holes shown use appropriately rated fasteners for both location and surface material and construction Fasten ers should be no larger than M6 Use the supplied countersunk M10...

Страница 21: ...nose keys The fixture can be tilted in any orientation To adjust the tilt angle in POI fixtures Loosen the two tilt lock kobs one on each side by turning them counter clockwise using the small pig no...

Страница 22: ...ut the SGM POI DMX cable For permanent installations have a qualified electrician wire the mains cable directly to a suitable branch circuit For a temporary installation the mains cable may be fitted...

Страница 23: ...indicator and wait for 3 sec onds The LED indicator will blink orange for 1 2 seconds before switching to static green again The fixture can now be paired to a new transmitter STEP 2 Select connect or...

Страница 24: ...n Control menu Before turning on the i 6 make sure the power cable is properly connected When the fixture is powered on it will boot and reset before displaying the selected operating mode and DMX sta...

Страница 25: ...erational mode B DMX address C External data indicator DMX D External data protocol next available DMX address Figure 17 i 6 Display EXTERNAL DATA PROTOCOL D Shows the external data protocol CRMX or D...

Страница 26: ...first 6 DMX channels including channel 101 the next avail able channel is 107 101 6 107 107 If two or more i 6s have the same DMX start address they will behave identically Incorrect settings will re...

Страница 27: ...e pro grams can be defined and run from the menus and one of the pro grams can be set to run by default whenever the fixture is powered on Each of the three available standalone programs contains 24 u...

Страница 28: ...dimming curve Flipping the OLED display If the fixture is installed hanging upside down it is useful to flip the display so that it is easier to read To flip the display press ENTER and select SETTING...

Страница 29: ...e refresh rate frequency of the LEDs to be Dimmer optimized low frequency flicker can occur on cameras highest dimming resolution High frequency optimized low dimming resolution flicker is unlikely to...

Страница 30: ...ss log off Send Log off command to the CRMX System BRIDGE DMX Displays strength of the wireless connection Startup Mode Select Startup Mode Default operating mode when fixture is powered on STARTUP MO...

Страница 31: ...selected scene 1 24 Red Red value in currently selected scene 0 255 Green Green value in currently selected scene 0 255 Blue Blue value in currently selected scene 0 255 Strobe Strobe blinders intens...

Страница 32: ...t control over the supported parameters See the tables below for supported RDM functions PLEASE NOTE THE RDM CONTROLLER COMMUNICATES WITH THE FIXTURES TO SHOW ONLY THE AVAILABLE OPTIONS FOR EACH RDM F...

Страница 33: ...for all SGM IP rated fixtures made for testing the IP integrity upon reassembly In order to ensure the IP rating of the i 6 Series it s highly recom mended that the fixture is always vacuum tested aft...

Страница 34: ...on the SGM website Connect either Std or POI uploader cable depending on which is more suitable for the installation Launch SGM Firmware Tool on a windows PC Click File then Open and navigate to the f...

Страница 35: ...aning as they can cause damage to hard ware cables and connectors The level of cleaning required will vary greatly depending on the operating environment and installation Therefore it is recommended t...

Страница 36: ...tions DMX cables was disconnected Inspect DMX cables Fixture operates irregularly abnor mal DMX cable polarization is inverted pin 2 3 Reverse the polarity DMX link is not terminated Install a XLR 120...

Страница 37: ...76 i 6 RGBW 2 3deg POI CU P N 80251777 i 6 RGBW 3 4deg POI CU P N 80251792 i 6 RGBW 3 4deg POI WH P N 80251791 i 6 RGBW 3 4deg POI BL P N 80251790 i 6 White POI I 6 W 2 3deg POI CU P N 80251782 I 6 W...

Страница 38: ...2011 65 EU RoHS2 Directive Pending ANSI UL Std 1573 Pending CSA Std C22 2 No 166 The information in this document is subject to chance without notice For the latest information visit www sgmlight com...

Страница 39: ...39 Product Version 1 0 Revision A Released 2022 4 21 USER NOTES...

Страница 40: ...40 Product Version 1 0 Revision A Released 2022 4 21 SGM LIGHT A S Sommervej 23 8210 Aarhus V Denmark Tel 45 70 20 74 00 info sgmlight com www sgmlight com...

Отзывы: