background image

28

RDM

The P-1 features support for various RDM functions. 
RDM (Remote Device Management) is a protocol enhancement to USITT DMX512 that allows bi-directional communication 
between the fixtures and the controller over a standard DMX line. This protocol will allow configuration, status monitoring, and 
management. See the table below for supported RDM functions.

The controller communicates with the fixtures to show only the available options for each RDM function.

The P-1 supports and enable RDM, Remote Device Management, as per the ANSI E1.20 standard.

PID

Actions

Allowed

Name

PID

Actions

Allowed

Name

0x00F0

GET SET

DMX Start Address

0x0080

GET

Device Model Description

0x00E0

GET SET

DMX Personality / Mode

0x0400

GET

SET

Device Hours

0x00E1

GET

DMX Personality Description

0x0051

GET

Parameter Description

0x1000

GET SET

Identify

0x0501

GET

SET

Display Level, 0=OFF, 1 and above=ON

0x1001

SET

Reset Device

0x0500

GET

SET

Display Invert

0x0200

GET

Sensor Definition

0x8626

SET

CRMX Log Off

0x0201

GET SET

Sensor Value

0x8631

GET

SET

Battery Extension Hours

0x0082

GET SET

Device Label

0x0090

SET

Factory Defaults

0x0081

GET

Manufacturer Label

0x8060

GET

Serial Number

Содержание 80031501

Страница 1: ...P 1 WASH LIGHT...

Страница 2: ...2 Dimensions Measurements in millimetres Drawing not to scale...

Страница 3: ...ty to use or reliance on the information contained in this manual The SGM logo the SGM name and all other trademarks in this document pertaining to services or products by SGM or its affiliates and su...

Страница 4: ...fire 9 LI ION battery 10 Avoid personal injury 11 Overview 12 Parts identification and terminology 13 Preparing for installation 14 Unpacking 14 Location application 15 Transportation 15 Installation...

Страница 5: ...Display 22 Wireless signal strength 22 Current input type 22 Current DMX address 22 Current power source Current battery level 22 Connecting to a DMX control device 23 Connecting a wireless transmitte...

Страница 6: ...0 Upgrading the firmware 31 Control menu 32 Factory defaults 36 LED panels 36 DMX modes overview 37 DMX protocol 39 1 x RGB 3 channel calibrated 39 4 channel RAW 40 2 x RGB 6 channel calibrated 41 6 c...

Страница 7: ...7 Effects 52 Troubleshooting 53 Fixtures and accessories 55 Included items 55 Ordering information 55 Approvals and certifications 56 User s notes 57...

Страница 8: ...le code d installation pertinent par une personne qui conna t bien le produit et son fonctionnement ainsi que les risques inh rent Preventing electric shock Always power off unplug the fixture before...

Страница 9: ...to be illuminated Install only in accordance with applicable building codes Do not paint cover or modify the fixture Keep all flammable materials away from the fixture Allow the fixture to cool for 1...

Страница 10: ...and a shortened life expectancy Do not place the battery in microwave ovens high pressure containers or on induction cookware Immediately discontinue use of the battery if while using charging or stor...

Страница 11: ...injury when working at height Ensure that the fixture is always securely fastened with suitable hardware For elevated installations secure the fixture with suitable safety cables and always comply wit...

Страница 12: ...nology its standard 10 beam angle can be manipulated in various ways Shape the beam and achieve different beam angles with an optional set of four magnetic holographic filter frames 19 45 63 x12 ellip...

Страница 13: ...ation and terminology A Dehumidifiers and GORE TEX membranes B DMX in and out C Power in D Display panel E Holes for omega bracket F Kensington lock socket G Base bracket H Safety wire attachment poin...

Страница 14: ...re that it has not been damaged in transport The P 1 is shipped with User manual One Neutrik TRUE1 power input connector 2 m 78 in One Omega bracket with 1 4 turn fasteners Filters optional Ceiling wa...

Страница 15: ...cted from contact with people It is not immersed in water or exposed to high pressure water jets It has adequate ventilation When using the fixture outdoors or in wet locations ensure that For wireles...

Страница 16: ...ned fully clockwise Always fasten a safety wire between the load bearing support structure and the attachment point on the fixture The safety cable must be able to bear at least 10 times the weight of...

Страница 17: ...8 8 and lock nut 3 Align the omega bracket with two 1 4 turns in the base bracket Insert the fasteners into the base bracket and turn both levers a full 1 4 turn clockwise to lock 4 Working from a st...

Страница 18: ...llation Loosen the lock screw on the ceiling wall mount Install the ceiling wall mount to the surface Position the fixture over the four slide locks and slide to the locked position Fasten the lock sc...

Страница 19: ...a Neutrik TRUE1 power connector supplied with the fixture The P 1 can also run on battery power up to 12 hours with the possibility to extend the battery time up to 24 hours For permanent installation...

Страница 20: ...rged state to full voltage and 70 of full capacity 3 5 hours 100 of full capacity 6 5 hours After 1000 full cycles the expected battery capacity will be 85 of the initial capacity Full cycle 0 to 100...

Страница 21: ...menu or make a selection Press the arrow buttons to scroll up and down the menus Press the ESC button to take a step back Press the UP and DOWN arrows simultaneously to flip the display upside down To...

Страница 22: ...Current DMX address Displays the current DMX address The DMX address is altered directly from this view The next available DMX address is displayed to the right The DMX address will flash on no data...

Страница 23: ...65 rating Connecting a wireless transmitter If the P 1 is not paired to a wireless transmitter it is designed to look for wireless transmitters in connect state To connect the P 1 to a wireless transm...

Страница 24: ...t settings will result in unpredictable responses to the lighting controller DMX start address The DMX address is the first channel used to receive instructions from the controller known as the DMX st...

Страница 25: ...ach scene has a definable fade in time for the transition from one color to the next and a wait static time each of up to 120 minutes and 59 seconds in duration To define a stand alone program use the...

Страница 26: ...ertical plus an empty color frame The frames are easily mounted due to their magnetic capabilities Installing the frames only requires positioning it in front of the light and it quickly snaps in to p...

Страница 27: ...Pull the two lock pins to the unlocked position and place the barndoor on the front of the head Release the lock pins and check that the lock pins are correctly in place Attach a safety wire to the b...

Страница 28: ...nable RDM Remote Device Management as per the ANSI E1 20 standard PID Actions Allowed Name PID Actions Allowed Name 0x00F0 GET SET DMX Start Address 0x0080 GET Device Model Description 0x00E0 GET SET...

Страница 29: ...le sensors and sensor types Name Sensor Type Name Sensor Type Main Board Temp Temperature AC power connected Contacts LED left Temperature Battery PCT percentage Other LED right Temperature Battery ch...

Страница 30: ...at frequent intervals within the first few weeks of operation to see whether cleaning is necessary This procedure will allow an assessment of cleaning requirements in the particular installation envi...

Страница 31: ...RMWARE VERSION To perform firmware updates use a Windows based personal computer the SGM Firmware Tool software available on the SGM website www sgmlight com and a SGM USB 5 Pin XLR upload cable avail...

Страница 32: ...7 MANUAL QUICK COLOR RED GREEN BLUE RUN PROGRAM STOP PROGRAM EDITOR PROGRAM 1 3 Select program to edit SCENE 1 24 Select scene to edit RED 0 255 Set value for red GREEN 0 255 Set value for green BLUE...

Страница 33: ...INFO PRODUCT TYPE Show product type FIRMWARE VERSION Show the current software version SERIAL NUMBER Show the fixture s serial number RDM ID Show the fixture s RDM ID DMX VIEW View DMX data and DMX ra...

Страница 34: ...STARTUP PROGRAM 1 3 Select program to run at start up AC POWER LOSS FUNCTION BATTERY BACKUP Continue on battery power upon loss of AC power Default EMERGENCY LIGHT Turn on white static light upon los...

Страница 35: ...installed in the fixtures needs to be set in order to calculate the battery extension feature PWM OUT Show the actual PWM output to the light source TEST SELFTEST Test all features of the fixture DISP...

Страница 36: ...MX Screen saver Off Flip screen Off Power loss function Battery backup RDM device label set to Fixture type name Internal program reset LED panels The P 1 offers the possibility to separate the LEDs i...

Страница 37: ...1 Red 1 Red 1 Red PANEL 1 2 Green 2 Green 2 Green PANEL 1 3 Blue 3 Blue 3 Blue PANEL 1 4 White 4 Red PANEL 2 9 channel calibrated 5 Green PANEL 2 MSB LSB Name 6 channel calibrated 6 Blue PANEL 2 1 Shu...

Страница 38: ...rated MSB LSB Name MSB LSB Name 1 Shutter 1 Shutter 2 Intensity 2 3 Intensity 3 CTC 4 CTC 4 Red PANEL 1 5 6 Red PANEL 1 5 Green PANEL 1 7 8 Green PANEL 1 6 Blue PANEL 1 9 10 Blue PANEL 1 7 White PANEL...

Страница 39: ...e DMX Percentage Description Info Default DMX Value Fader Type 1 Red 0 255 0 0 100 0 No Red Maximum Red All panels 255 100 Fade 2 Green 0 255 0 0 100 0 No Green Maximum Green All panels 255 100 Fade 3...

Страница 40: ...e Fader Type 1 Red 0 255 0 0 100 0 No Red Maximum Red All panels 255 100 Fade 2 Green 0 255 0 0 100 0 No Green Maximum Green All panels 255 100 Fade 3 Blue 0 255 0 0 100 0 No Blue Maximum Blue All pan...

Страница 41: ...100 Fade 2 Green PANEL 1 0 255 0 0 100 0 No Green Maximum Green PANEL 1 255 100 Fade 3 Blue PANEL 1 0 255 0 0 100 0 No Blue Maximum Blue PANEL 1 255 100 Fade 4 Red PANEL 2 0 255 0 0 100 0 No Red Maxim...

Страница 42: ...robe Fast Slow 152 175 59 6 68 6 Pulse Open Slow Fast 176 199 69 0 78 0 Pulse Close Slow Fast 200 244 78 4 95 7 Strobe Random Slow Fast 245 255 96 1 100 0 Open 2 Intensity 0 255 0 0 100 0 No light Max...

Страница 43: ...ription Info Default DMX Value Fader Type 4 Red 0 255 0 0 100 0 No Red Maximum Red All panels 255 100 Fade 5 Green 0 255 0 0 100 0 No Green Maximum Green All panels 255 100 Fade 6 Blue 0 255 0 0 100 0...

Страница 44: ...6 3 59 2 Strobe Fast Slow 152 175 59 6 68 6 Pulse Open Slow Fast 176 199 69 0 78 0 Pulse Close Slow Fast 200 244 78 4 95 7 Strobe Random Slow Fast 245 255 96 1 100 0 Open 2 Intensity 0 255 0 0 100 0 N...

Страница 45: ...me DMX Value DMX Percentage Description Info Default DMX Value Fader Type 5 Blue 0 255 0 0 100 0 No Blue Maximum Blue All panels 255 100 Fade 6 White 0 255 0 0 100 0 No White Maximum White All panels...

Страница 46: ...robe Fast Slow 152 175 59 6 68 6 Pulse Open Slow Fast 176 199 69 0 78 0 Pulse Close Slow Fast 200 244 78 4 95 7 Strobe Random Slow Fast 245 255 96 1 100 0 Open 2 Intensity 0 255 0 0 100 0 No light Max...

Страница 47: ...en PANEL 1 0 255 0 0 100 0 No Green Maximum Green PANEL 1 255 100 Fade 6 Blue PANEL 1 0 255 0 0 100 0 No Blue Maximum Blue PANEL 1 255 100 Fade 7 Red PANEL 2 0 255 0 0 100 0 No Red Maximum Red PANEL 2...

Страница 48: ...e Fast Slow 152 175 59 6 68 6 Pulse Open Slow Fast 176 199 69 0 78 0 Pulse Close Slow Fast 200 244 78 4 95 7 Strobe Random Slow Fast 245 255 96 1 100 0 Open 2 Intensity 0 255 0 0 100 0 No light Maximu...

Страница 49: ...PANEL 1 0 255 0 0 100 0 No Blue Maximum Blue PANEL 1 255 100 Fade 7 White PANEL 1 0 255 0 0 100 0 No White Maximum White PANEL 1 255 100 Fade 8 Red PANEL 2 0 255 0 0 100 0 No Red Maximum Red PANEL 2...

Страница 50: ...obe Fast Slow 152 175 59 6 68 6 Pulse Open Slow Fast 176 199 69 0 78 0 Pulse Close Slow Fast 200 244 78 4 95 7 Strobe Random Slow Fast 245 255 96 1 100 0 Open 2 3 Intensity 0 255 0 0 100 0 No light Ma...

Страница 51: ...EL 1 0 255 0 0 100 0 No Green Maximum Green PANEL 1 255 100 Fade 9 10 Blue PANEL 1 0 255 0 0 100 0 No Blue Maximum Blue PANEL 1 255 100 Fade 11 12 Red PANEL 2 0 255 0 0 100 0 No Red Maximum Red PANEL...

Страница 52: ...rom 2000 Kelvin 10000 Kelvin Ultra high speed strobe effect The ultra high speed strobe effect 1 50 Hz introduces the possibility to strobe up to 50 times per second Random strobe and pulse effects ca...

Страница 53: ...GM service partner Fixture suddenly turned off Power was turned off Check the power supply switches and breakers The fixtures batteries are discharged Charge the batteries by connecting AC power Fixtu...

Страница 54: ...f configured so See AC POWER LOSS FUNCTION in the Control menu on page 32 To turn off the fixture press and hold ESC until the fixture turns off or go to MENU POWER OFF When operating on battery power...

Страница 55: ...er no 82051010 P 1 ceiling wall mount Order no 83060614 Filter frame Medium angle 19 deg P 1 series Order no 83061140 Filter frame Wide angle 45 deg P 1 series Order no 83061141 Filter frame Elliptica...

Страница 56: ...CERTIFICATIONS Conforms to 2014 30 EU EMC Directive Conforms to 2014 35 EU Low Voltage Directive Conforms to 2011 65 EU RoHS2 Directive RoHS PENDING The information in this document is subject to chan...

Страница 57: ...57 User s notes...

Страница 58: ...58...

Страница 59: ...59...

Страница 60: ...SGM Light A S Sommervej 23 8210 Aarhus V Denmark Tel 45 70 20 74 00 info sgmlight com www sgmlight com...

Отзывы: