Do not throw lithium batteries into fire, do not solder on the cell body, do not recharge, do
not open, do not short-circuit, do not reverse polarity, do not heat above 100°C and protect
from direct sunlight, moisture and condensation.
Dispose of used batteries according to local regulations and the battery manufacturer's
instructions.
Before opening the Strato Pi CM case, disconnect all power sources and any connection
to external devices, including USB cables.
Use a non-conductive pin or small tool to help extract the battery from its holder. Insert the
new battery with a gentle push. You don't need tools to insert the battery. The battery is
held into place by a spring contact.
Be sure to insert the battery so that the negative (-) terminal is facing the vertical circuit
board, and touches the contact pad at the center of the battery holder, as shown in the
photo below.
Reversing the battery polarity may damage the product.
The real time clock will reset its time immediately when the RTC backup battery is
disconnected.
RTC BACKUP BATTERY HOLDER
RTC BACKUP BATTERY INSTALLED
NOTICE
13
Strato Pi CM User Guide