7HENCLAIMINGAWARRANTYREPAIRWEWILLNEEDTHEINFORMATIONYOUHAVEWRITTENDOWNBELOW0LEASEENSURETHATYOUHAVEALL
PARTICULARSAVAILABLEWHENREQUESTINGWARRANTYWORK
.AME/WNER
___________________________________________________________________________________________________________
)NSTALLATION!DDRESS
_____________________________________________________________________________________________________
0URCHASED&ROM
________________________________________________________________________________________________________
)NSTALLED"Y
____________________________________________________________________________________________________________
$ATEOF0URCHASE
_______________________________________________________________________________________________________
________________________________________________________________________________________________________________________
3ERIAL.UMBER
__________________________________________________________________________________________________________
$ATEOF-ANUFACTURE
_______________________________________________________________________
SEEMANUFACTURERSTAGONUNIT
7
TROUBLE SHOOTING GUIDE
PROBLEM
-OTORTURNSNORMALLYBUTTHEWATER
EVACUATESSLOWLYFROMTHEBOWL
FLUSHINCOMPLETE
7ASTEBUILDUPINBOWL
4HEMACERATINGUNITDOESNOTSTART
UP7ATERDOESNOTEVACUATE
4HEMOTORHUMSBUTDOESNOTTURN
THEWATERDOESNOTEVACUATE
7ATERGOESDOWNSLOWLYANDMOTOR
WORKSINTERMITTENTLY
4HEWATEREVACUATESFROMTHETOILET
BUTTHEMOTORRUNSFORAVERYLONG
TIMETHERMALOVERLOADACTIVATES
!FTEREVACUATIONTHEMOTORENGAGES
SEVERALTIMESINSUCCESSIONBEFOREIT
STOPSCOMPLETELY
-OTORTURNSNOISILYWITHOUTSTOPPING
ORPUMPING
!FTEREVACUATIONTHEMOTORSTARTS
STOPSANDREENGAGESINDEFINITELY
&OR3ANITOPTHEMOTORTURNSWITHA
RATTLINGNOISE
7ATERBACKSUPINTOSHOWERTRAYOR
BATHTUB
CAUSE
$ISCHARGEPIPEBLOCKEDORVALVENOT
VENTEDPROPERLY
)NADEQUATEWATERSUPPLYFROM
RESERVOIR
0OWERSUPPLYOFF4HERMALOVERLOAD
CUTOUT
&OREIGNBODYBLOCKINGTHEMACERA
TINGBLADES$EFECTIVECAPACITOR
#LOGGEDUPSANITARYNAPKINNEWS
PAPERPLUGGEDBREATHERHOLEETC
+INKEDBLOCKEDDISCHARGEPIPE
DAMAGEDMEMBRANEDEFECTIVE
IMPELLERANDPARTIALLYBLOCKEDPUMP
7ATERSIPHONSBACKINTOTHE
MACERATINGUNIT#HECKVALVE
ISNOTFUNCTIONINGPROPERLY
3IPHONAGEORINSUFFICIENTBACK
PRESSUREINDISCHARGEPIPECAUSING
AIRLOCK&OREIGNOBJECT
7ATERLEAKINGFROMRESERVOIRINTO
BOWL&AULTYNONRETURNCHECKVALVE
3OLIDITEMHASFALLENINTOTHEGRILLEOF
THEMACERATINGUNIT
)NADEQUATEGRAVITYFALLINTOMACERA
TINGUNITORBLOCKAGEINDRAINPIPING
&AULTYINLETCONTROLFLAP
REMEDY
#LEANOUTTHEPIPINGANDAIRBREATHER
HOLE
#HECKANDORADJUSTWATERLEVELIN
RESERVOIR
7AITFORTHERMALOVERLOADTOENGAGE
APPROXMIN
3EEhDISMANTLINGv
&LUSHORTIMESTOCLEAR#LEANING
ORDISMANTLINGMAYBEREQUIRED
#LEANOUTTHEBREATHERHOLE
#HECKINSTALLATION
&LUSHONCEORTWICEWITHCLEANWATER
TOCLEARVALVEORREMOVEVALVETO
CLEAN
-ODIFYDISCHARGEPIPERUNTO
ELIMINATESIPHONAGEANDORINCREASE
BACKPRESSURE%GREDUCEPIPESIZE
PUTEXTRABENDINRUN2EMOVE
FOREIGNOBJECT
#HECKFLUSHVALVE#HECKANDCLEAN
NONRETURNCHECKVALVE
#LEAROBJECTFROMGRILLEAREA
/
vPERFOOTGRAVITYFALLMINIMUM
INTOMACERATINGUNITFROMOTHERSANI
TARYFIXTURES
#LEANOUTTHEFLAP
IMPORTANT