Содержание Saniswift Pro

Страница 1: ...numéro suivant 800 571 8191 USA or 800 877 8538 CDN This product must be installed in strict accordance with local plumbing codes Product should be installed by a licensed plumber Le produit doit être installé dans le respect des règlements sanitaires locaux Le produit doit être installé par un plombier qualifié C US C US USA CAN The user should retain these instructions for future reference À lir...

Страница 2: ...mn Débit US gallon mn VERTICAL DISTANCE ft DISTANCE VERTICALE ft 14 9 6 3 0 0 5 10 15 20 25 30 35 40 6 14 ft 140 ft B x 1 C x 1 D x 4 E x 1 H x 2 G x 2 32 50 40 60 DISCHARGE ÉVACUATION A x 1 F x 2 50 70 3 4 A1 A2 5 1 4 Ø1 1 2 Ø1 1 4 Ø1 15 10 1 2 C B A ...

Страница 3: ...3 7 7d F A1 F G H D E B 7c 6 min 8 recommended conseillé per foot gravity fall par pied de la pente gravitaire 1 Vent Aération 7a YES NO D C A2 7e D D 2 Hole saw Scie cloche 2 ...

Страница 4: ...ECTION TO A VENTILATION SYSTEM The unit has been designed with a vent connection on the top of the pump All plumbing codes require a connection to a vent system Connect your vent system using the provided 1 1 2 x 1 1 2 rubber coupling to connect to your PVC pipe DISCONNECT THE POWER SUPPLY BEFORE ATTEMPTING ANY WORK ON THE DEVICE Please note that the vent system should be a two way air vent The us...

Страница 5: ... accordance with the pipe manufacturer s recommendations Avoid dipping or trapping which may cause the build up of residual solids and subsequent blockage BENDS Where possible long sweeping bends should be used Do not use short el bows If sweeping 90 elbows are not available use two 45 elbows to make a 90 turn PIPE WORK All pipe work should be either cop per PVC or CPVC Do not use flexible pipes H...

Страница 6: ...bject to the Terms and Conditions above in no event shall the company be liable for any special incidental or conse quential damage loss or injury of whatsoever nature or kind arising from or associated with the product or any component thereof Refer to section F for more details and information on warranty coverage exemptions 5 This warranty is transferable only when the product remains at the sa...

Страница 7: ... Avenue Suite A Edison NJ 08837 SFA SANIFLO INC 500 Jamieson Parkway Unit 5 Cambridge ON N3C 0G5 Toll Free Telephone Fax E mail Web Site 1 800 571 8191 1 732 225 6070 1 732 225 6072 sfasales saniflo com www saniflo com Toll Free Telephone Fax E mail Web Site 1 800 363 5874 1 519 824 1134 1 519 824 1143 sfasales saniflo ca www saniflo ca EN US ...

Страница 8: ...tilisation sur le territoire du Canada et des Etats Unis Ceci inclut les produits satisfaisant aux conditions requises pour porter la mention NTRL La mention NTRL Nationally Recognized Testing Laboratory labo ratoire d essai reconnu nationalement est une appellation décer née par la Occupational Safety and Health Administration OSHA Agence pour la sécurité et la santé au travail américaine aux lab...

Страница 9: ...urer l écoulement absolu par gravité pour que le drainage se fasse librement lorsque la pompe s arrête PAS DE TUYAUX EN DIAGONALE Tous les tuyaux de vidange sortant de l appareil doivent soit monter directement à la verticale soit être en position horizontale avec un léger écoulement par gravité jusqu au point d évacuation Il ne faut pas installer de tuyaux en diagonale entre l appareil et le poin...

Страница 10: ...t de l appel téléphonique 4 Sous réserve des conditions générales ci dessus la Compagnie ne pourra en aucun cas être tenue responsable pour tout dommage perte ou blessure spécial accidentel ou consécutif de quelque nature que ce soit résultant de ou associé au pro duit ou à l un de ses composants Se reporter à la section F pour plus de détails et d informations sur les exemptions de garantie 5 Cet...

Страница 11: ...e A Edison NJ 08837 SFA SANIFLO INC 500 Jamieson Parkway Unit 5 Cambridge ON N3C 0G5 Numéro sans frais Téléphone Télécopieur Courriel Site Web 1 800 571 8191 1 732 225 6070 1 732 225 6072 sfasales saniflo com www saniflo com Numéro sans frais Téléphone Télécopieur Courriel Site Web 1 800 363 5874 1 519 824 1134 1 519 824 1143 sfasales saniflo ca www saniflo ca ...

Страница 12: ...EXPLODED DRAWING DESSIN ÉCLATÉ 10 2 3 4 5 6 7 8 9 11 10 1 12 13 15 14 16 17 18 ...