Installing the MOVI-PLC® advanced DHF41B controller
Mounting/Installation Instructions
For PROFIBUS mode: DIP
switches
for setting
the PROFIBUS
Station address
For operation via
DeviceNet:
DIP switches
for setting
The MAC-ID and for set-
ting the baud rate
2
0
2
1
2
2
2
3
2
4
2
5
2
6
2
0
2
1
2
2
2
3
2
4
2
5
2
6
2
7
Significance: 1
Significance: 2
Significance: 4
Significance: 8
Significance: 16
Significance: 32
Significance: 64
The DIP switches 2
0
... 2
5
are used to set the
MAC-ID (
M
edia
A
ccess
C
ontrol
Id
entifier).
The MAC-ID represents the node address
(address range 0 ... 63)
Setting the baud rate
Setting the baud rate
Connector X38:
SafetyBus
(plug-in terminals)
X38:1
X38:2
X38:3
Reserved
Reserved
Reserved
Terminal X31:
Binary inputs and out-
puts
(plug-in terminals, color:
BK))
X31:1
X31:2
X31:3
X31:4
X31:5
X31:6
X31:7
X31:8
X31:9
X31:10
+24 V input
REF24V
DIO 0
DIO 1
DIO 2
DIO 3
DIO 4
DIO 5
DIO 6
DIO 7
Voltage input DC+24 V
Reference potential for binary signals
Binary input or output
Binary input or output
Binary input or output
Binary input or output
Binary input or output
Binary input or output
Binary input or output
Binary input or output
Terminal X34:
RS485 interfaces COM1,
COM2
(plug-in terminals, color:
BK)
X34:1
X34:2
X34:3
X34:4
X34:5
X34:6
RS+
RS+ insulated
RS–
RS– insulated
DGND
GND insulated
Signal RS485+ (COM 1)
Signal RS485+ insulated (COM 2)
Signal RS485– (COM 1)
Signal RS485– insulated (COM 2)
Reference potential (COM 1)
Reference potential (COM 2)
Connector X35:
USB connection (in prep-
aration)
X35:1
X35:2
X35:3
X35:4
USB+5 V
USB–
USB+
DGND
DC 5 V power supply
Signal USB–
Signal USB+
Reference potential
Connector X36:
Connection Ethernet 1
System bus (RJ45
socket)
X36
Standard Ethernet assignment
Connector X37:
Connection Ethernet 2
(RJ45 socket)
X37
Terminal X32:
System bus CAN 2
(electrically isolated)
(plug-in terminals, color:
YE/BK)
X32:1
X32:2
X32:3
REF_CAN 2
CAN 2H
CAN 2L
Reference potential for system bus CAN 2
System bus CAN 2 high
System bus CAN 2 low
Terminal X33:
System bus CAN 1
(plug-in terminals, color:
YE/BK)
X33:1
X33:2
X33:3
DGND
CAN 1H
CAN 1L
Reference potential for system bus CAN 1
System bus CAN 1 high
System bus CAN 1 low
DIP switch S1
S1
Top
Bottom
Default IP address
Ethernet 2 connection
Reset button T1
T1
Reset
Front view
MOVI-PLC
®
advanced
DHF41B
controller
Designation
LED
DIP switches
Terminal
Function
Содержание DHE41B
Страница 2: ...SEW EURODRIVE Driving the world ...