![SEW DFD11B Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/sew/dfd11b/dfd11b_manual_1250019023.webp)
Manual – DFD11B DeviceNet Fieldbus Interface
23
5
Configuring PLC and master (DeviceNet scanner)
Project Planning and Startup
5.2
Configuring PLC and master (DeviceNet scanner)
The following samples refer to the usage of an Allen-Bradley-PLC ControlLogix 1756-
L61 together with the RSLogix 5000 programming software and the DeviceNet
RSNetWorx configuration software for DeviceNet.
After adding the DeviceNet Scanner to the I/O configuration, the file *.dnt containing the
DeviceNet configuration is selected. To view and edit the DeviceNet configuration,
RSNetWorx can be launched from this dialog (
→
following figure).
In RSNetWorx for DeviceNet (
→
following figure), either perform an online scan or add
the required devices to the graph by drag and drop. The address given under the icon
of the device must be equal to the MAC-ID set by the DIP switches of the DFD11B. If
the required devices are not in the selection list, corresponding EDS files have to be reg-
istered via [Tools] / [Wizard].
11744AXX
11745AXX
0
0
I
Содержание DFD11B