6.1
Basic units
MOVITRAC
®
type
0504-231-1
0508-231-1
Inverter part number 1Q
825 877 5
825 878 3
Rated output power
P
N
(at V
mains
= 1 x 230 V
AC
)
0.75 kVA
1.27 kVA
Continuous output power (110% P
N
)
P
cont
(at V
mains
= 1 x 230 V
AC
)
0.84 kVA
1.4 kVA
Rated supply voltage
V
mains
Permissible range
1 x 220 V
AC
/ 230 V
AC
/ 240 V
AC
V
mains
= 200 V
AC
- 10% ... 240 V
AC
+ 6%
Mains frequency
f
mains
50 Hz...60 Hz ± 10%
Mains rated current
I
mains
3.8 A
AC
6.3 A
AC
Output voltage
V
outp
Setting value PARA 44 VN1 or 47 VN2 however
max. V
mains
PWM frequency
f
PWM
Setting value PARA 74 PWM
(7.8 kHz / 15.6 kHz / 3.9 kHz)
Output frequency
f
outp
Permissible setting range: 0...400 Hz
f
min
= 0...400 Hz
f
max
= 4.0...400 Hz
Resolution
∆
f
outp
= 0.1% f
max
, maximum 0.05 Hz
Output rated current
I
N
1.9 A
AC
3.2 AAC
Recommended motor power
P
mot
0.375 kW
0.75 kW
Continuous output current
I
cont
I
cont
=110 % I
N
2.1 A
AC
3.5 A
AC
Overload
motoring: 150% I
N
or 138% I
cont
for t = 60 s
Braking resistor for 4Q operation
BRC 03 with integrated braking resistor
Interference emission
with EMC-compliant installation
(mains input screened motor cable)
to class B limit to EN 55011 + EN 55014,
complies with EN 50081 - Parts 1 and 2
Immunity
complies with EN 50082 - Parts 1 and 2
Ambient temperature
ϑ
amb
0...+40°C (P
N
derating: 3.0% I
N
per K up to max. 60°C)
Storage temperature
ϑ
storage
- 25°...+70°C
Enclosure
IP 20 (EN 60529)
Duty type
DB continuous (EN 60146-1)
Power losses at P
N
P
loss max
25 W
35 W
Type of cooling
KS = natural cooling (DIN 41 751)
Altitude of installation
h
≤
1000 m (P
N
derating: 5% per 1000 m from
1000 m to max. 2000 m)
Weight
1 kg
Main dimensions basic unit WxHxD
6 x 183 x 137 mm
Mounting dimensions
40 x 170 mm
Hole size
4.8 mm
Power ratings are based on a factory-set PWM frequency of 7.8 kHz.
To provide sufficient cooling leave the following minimum clearances:
●
With FKS 01 heat sink:
above and below each unit 50 mm and 30 mm on each side
●
Without heat sink mounted to switch cabinet rear panel:
above and below each unit 200 mm, 200 mm on each side, i.e. cooling area min. 0.25 m²
6
Technical Data
MOVITRAC
®
0500 - Operating Instructions
23