4.2
Operation with FBG 01 keypad
4.2.1
Connection and operating displays of the FBG 01 keypad
The MOVITRAC
®
0500 basic unit comes without keypad. The optional FBG 01 keypad can be used
to display and adjust the inverter parameters.
●
Disconnect the inverter from the supply and
wait for 2 minutes!
●
Turn the interlock to open the inverter cover and
remove lower cable gland.
●
Take out perforated centre piece from cable
gland (press to take out).
●
Pull through FBG 01 connecting cable.
●
Plug connector into socket X3 of the basic until
it snaps into place.
●
Re-insert cable gland and close cover.
●
Position FBG 01 onto the two pins on the
inverter cover and pull down until it snaps into
place.
●
To remove the FBG 01 again: push up and pull
off forwards.
Fig. 4: FBG 01 connection
00407AEN
1
LCD display
2
Arrow key [down]
3
Key [Stop/Return]
4
Labelling field for bar graph display
5
Arrow key [up]
6
Key [Start/Enter]
7
Optional ParaCard PAC 01
8
Connecting cable FBG 01 - inverter
9
Dimension for bar graph display
10 5-digit actual value and setpoint indication
11 PARA menu branch for parameter adjustment
12 VAL menu branch for display values
13 3-digit display, actual values/parameter
numbers
14 CCW direction of rotation
15 CW direction of rotation
16 Acceleration ramp
17 Deceleration ramp
18 CTRL menu branch for manual operation
19 CARD menu branch for reading/saving with
PAC 01
20, 21, 22 Dimension for 5-digit display
23 Bar graph display
Fig. 5: FBG 01 displays
00406AXX
5
6
7
8
9
10
4
3
1
2
11
+
+
stop
return
start
enter
V A L
Hz
SEW
EURODRIVE
+
+
= Closed
= Open
Lock bolt
Connector
Centre-piece
Cable opening
Socket X3
Fixing bolts
stop
return
start
enter
V A L
Hz
PAC 01
SEW
EURODRIVE
8
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
7
6
5
4
3
1
2
% VA
h min
Hz / s
-1
V A L
P A R A
C T R L
C A R D
4
Commissioning
12
MOVITRAC
®
0500 - Operating Instructions