4.4.2
PARA menu branch, adjustable parameters
Level
Data
set
No. Code
Function
Value range
(Factory setting
underlined)
Setting
after
commis-
sioning
1
2
3
1
2
X
X
X
1
MODE
Operating mode
0/1/2/3/4
X
2
CSEL
(Not for use)
Do not
change!
X
X
4
FSSEL
Frequency setpoint
selector
0, 4...15
X
5
FSSIO
(Not for use)
Do not
change!
X
X
9
BARG
Bar graph display
F, V, IS, IW, SIN, STAT
Frequencies
X
X
X
●
20
FFS2-1 Fixed frequencies 2-1
0.00... 3.00 ...999.00
X
X
X
●
21 FMIN1
Minimum frequency
0.00...999.00
X
X
X
●
22 FMAX1 Maximum frequency
4.00... 50.00 ...999.00
X
X
X
23 FF3
Fixed frequency 3
0.00... 15...999.00
X
X
X
24 FF4
Fixed frequency 4
0.00... 30...999.00
X
X
X
25 FF5
Reference frequency
S2OUT
0.00... 3.00 ...999.00
X
X
26 FF6
Control frequency
(characteristic)
0.00...999.00
X
X
●
27
FF2-2
Fixed frequency 2-2
0.00... 5...999.00
X
X
●
28
FMIN2 Minimum frequency
0.00...999.00
X
X
●
29
FMAX2 Maximum frequency
4.00... 50.00 ...999.00
Ramp generators
X
X
31
KSEL
Characteristic set selector 0 / 1 / 2 / 3
0
always data set 1
1
data set 2 if
12 F 26 FF6
2
data set 2 if
S2IND = “1"
3
data set 2 if CCW
X
X
X
●
32 RACC1 Acceleration ramp 1
0.10... 20.00 ...999.00 Hz/s
X
X
X
●
33 RDEC1 Deceleration ramp 1
0.10... 20.00 ...999.00 Hz/s
X
X
●
34
RACC2 Acceleration ramp 2
0.10... 80.00 ...999.00 Hz/s
X
X
●
35
RDEC2 Deceleration ramp 2
0.10... 80.00 ...999.00 Hz/s
X
X
X
36 RSTOP Stop ramp
0.00...999.00 Hz/s
Characteristic
X
X
38 THTDC Switch-off delay
0.00...120.00 s
X
X
39 VHTDC DC holding voltage
1.00... 4.00 ...25.00 %
X
X
X
41 V/FC
V/f characteristic selector
1/4
X
X
X
●
42
VBF
Boost 1 (starting torque)
0.00... 8.00 ...25.00 %
X
X
X
●
43
FN1
Base (rated) frequency 1
26.00... 50.00 ...960.00 Hz
X
X
X
●
44
VN1
Rated voltage 1
110... 220...240 V
X
X
●
45
VB2
Boost 2 starting torque)
0.00... 8.00 ...25.00 %
X
X
●
46
FN2
Base (rated) frequency 2
26.00... 50.00 ...960.00 Hz
X
X
●
47
VN2
Rated voltage 2
110... 220...240 V
4
Commissioning
18
MOVITRAC
®
0500 - Operating Instructions