![SEVEN WR-Z16 Скачать руководство пользователя страница 78](http://html.mh-extra.com/html/seven/wr-z16/wr-z16_user-manual_1247543078.webp)
Chapter 5:
Timing
78
v3.3-a 12/07/2022
Delay Req ratio
[1 msg/128s,128 msg/s] ([-7,7])
1 msg/sec
Clock Quality & Timing Properties
Clock Class
From VCS or user defined (0-255)
248
Priority1
From VCS or user defined (0-255)
128
Priority2
From VCS or user defined (0-255)
128
Clock Accuracy
From VCS (See §0)
Unknown
Variance
From VCS
65535 (maximum)
Timing Source
From VCS (See §0)
OTHERS
Traceability Flags
From VCS
False
PTP Timescale
From VCS or user defined
True
UTC Offset
From VCS
37
Advanced Settings
Offset correction
Any number (in nanoseconds)
0
Servo Fit Algorithm
Normal, Soft, Hard, Hardx2
Normal
Table 5:4 - IEEE 1588 configuration with/without license
5.4.1.1 PTP license management
All the topics related to PTP license management such as purchasing, activating and checking are
explained within the 8.1 Licenses section (§0).
Once the license is activated (Figure ) the web interface should allow the user to configure these
settings as explained in §0.
Figure 5:15 - Unlicensed VS Licensed PTP daemon
The CLI tool allows to modify and save all the parameters listed in Table 5:4 even
without license. However, they will not be Applied/Loaded until the PTP license is
validated.
5.4.2 Configuration
Master/Slave port configuration
The role of the port is given by the Preset (§0) and cannot be modified directly from the
Содержание WR-Z16
Страница 2: ...Chapter 1 Introduction 2 v3 3 a 12 07 2022 ...
Страница 10: ...Chapter 1 Introduction 10 v3 3 a 12 07 2022 ...
Страница 72: ...Chapter 5 Timing 72 v3 3 a 12 07 2022 ...
Страница 148: ...Chapter 8 Device Maintenance 148 v3 3 a 12 07 2022 ...
Страница 159: ...Chapter 9 Troubleshooting 159 v3 3 a 12 07 2022 Severity info local0 rsyslog server1 IP local0 rsyslog server2 IP ...