3.3.1 Logging from UART
In order to connect to the WR-ZEN device, it is required to connect the RJ45-RS232(m) and
RS232(f)-USB cable to the RJ45 management port at the front panel.
Multiple software can be used to read from the UART in the computer depending on the
operating system used for that purpose (e.g. Minicom, Picocom or Putty). Learn more in the
below sections.
Table 3:2 summarizes the settings required to connect to the serial port (UART) of the device
Setting Value
Baud Rate 115200bps
Data 8 bits
Parity None
Stop bits 1 bit
Flow Control none
Table 3:2 - UART settings
3.3.2 Logging from SSH
Remote authentication servers (/Radius)
If there is any remote authentication server configured and it is responding, the
local credentials of the user root
will not
be used. Only if the remote server is not
working or is unreachable, will the local credentials be available again. This can
render the device accessible only by UART.
There are three main ways to connect to the WR-ZEN device from SSH:
1.
Using default static IP on eth1:
○
Connect the RJ-45 Ethernet cable to the
eth1
interface.
○
Connect the host interface to the same LAN and configure its IP address to be
within the same netmask.
○
Access to the device by typing in the host terminal:
2.
Using a DHCP server on eth0
:
○
Connect the RJ-45 Ethernet cable to the
eth0
interface to a LAN network with a
running DHCP server.
Содержание WR-Z16
Страница 2: ...Chapter 1 Introduction 2 v3 3 a 12 07 2022 ...
Страница 10: ...Chapter 1 Introduction 10 v3 3 a 12 07 2022 ...
Страница 72: ...Chapter 5 Timing 72 v3 3 a 12 07 2022 ...
Страница 148: ...Chapter 8 Device Maintenance 148 v3 3 a 12 07 2022 ...
Страница 159: ...Chapter 9 Troubleshooting 159 v3 3 a 12 07 2022 Severity info local0 rsyslog server1 IP local0 rsyslog server2 IP ...