![Sesamo smart PRO Скачать руководство пользователя страница 81](http://html1.mh-extra.com/html/sesamo/smart-pro/smart-pro_operating-instructions-manual_1247168081.webp)
81
SESAMO
SMARTPRO
Note:
Diagnostics to identify the operator failure
SIGNAL
DESCRIPTION
E1
Door needs self learning
procedure (see Paragraph “Start up”)
E5
Missing Main-Key
E6
Error in the configuration of the monitoring sensors
(Need to set parameter 18)
E7-5
Electrical overcurrent detection
E7-6
Time-out Movement (greater than
60”)
E7-A
Overload power tension out of tolerance
E8-1
Error Test connection Motor and Encoder
(Verificare la connessione del Motore e dell’Encoder).