![Sesamo smart PRO Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/sesamo/smart-pro/smart-pro_operating-instructions-manual_1247168053.webp)
53
SESAMO
SMARTPRO
After wiring set parameter 18 as follows:
14.
Only safety sensor in closing A
–
set parameter 18 at level 1
15.
Solo safety sensor in opening B
–
set parameter 18 at level 2
16.
Both safety sensors A e B
–
set parameter 18 at level 3
Control board when powered on will indicate the type of sensors’ configu
ration according the following
table:
ID
CONFIGURATION
DESCRIPTION
S0
No monitored sensors
detected
There are no monitored sensors wired or the sensors detected
will be managed as normal sensors without monitoring.
S1
Monitored sensor only in
opening.
There is only monitored sensor in opening. In closing there is no
sensor connected or the sensor connected will be managed as
normal sensor without monitoring.
S2
Monitored sensor only in
closing.
There is only monitored sensor in closing. In opening there is no
sensor connected or the sensor connected will be managed as
normal sensor without monitoring.
S3
Monitored sensor in
opening and closing.
Monitored sensor wired in opening and closing.
In case of incorrect connection or malfunction of the sensors, the display of the control board will show
“F”
blinking followed by a number:
F1
Monitored sensor only in
opening.
Safety sensor in opening is not connected or it does not work
properly
F2
Monitored sensor only in
closing.
Safety sensor in closing is not connected or it does not work
properly
F3
Monitored sensor in
opening and closing.
Both safety sensor in opening and closing are not connected or
they do not work properly
DANGER: Before confirming the acquisition, carefully check that the configuration detected by the
control board is appropriate for the installation and verify that all safeties are detected correctly.
Otherwise safety may not be granted and the automatic movement of the doors could cause serious
damage to property or people at risk of life-threatening injuries.
Содержание smart PRO
Страница 1: ...1 SESAMO SMARTPRO AUTOMATISM FOR SWING DOORS OPERATING INSTRUCTIONS ENGLISH...
Страница 33: ...33 SESAMO SMARTPRO Arm in closed position...
Страница 38: ...38 SESAMO SMARTPRO 4 Refit switching and control board insert cable connector in the dedicated electric clamp...
Страница 68: ...68 SESAMO SMARTPRO 28 WIRING AND USE OF INTERLOCK With priority Without priority...