background image

 

CDHD2 

20 

Operator Panel (HMI) 

Parameter  

Description 

Code 

OUTBRAKEINV 

Manual Brake by Output Inverse  

P 4 0 4 2  

OUTBRAKEMODE 

Manual Brake by Output Mode 

P 4 0 4 3  

OUTFLTLVL 

Force Digital Output State on Fault 

P 4 0 4 4  

OUTILVL1 

Current 1 Digital Output Definition 

P 4 0 4 5  

OUTILVL2 

Current 2 Digital Output Definition 

P 4 0 4 6  

OUTINV 

Position 1 Digital Output Definition 

P 4 0 4 7  

OUTPLVL2 

Position 2 Digital Output Definition 

P 4 0 4 8  

OUTVLVL1 

Velocity 1 Digital Output Definition 

P 4 0 4 9  

OUTVLVL2 

Velocity 2 Digital Output Definition 

P 4 0 5 0  

RELAY 

Fault Relay Status 

P 4 0 5 1  

RELAYMODE 

Fault Relay Mode 

P 4 0 5 2  

Analog I/Os 

Starting at index 4200 

 

ANIN1DB 

Analog Input 1 Deadband 

P 4 2 0 0  

ANIN1FILTAFF 

Analog Input 1 MSQ 2nd Deriv FF 

P 4 2 0 1  

ANIN1FILTIN 

Analog Input 1 Before MSQ Filter 

P 4 2 0 2  

ANIN1FILTMODE 

Analog Input 1 MSQ Filter 

P 4 2 0 3  

ANIN1FILTT1 

Analog Input 1 MSQ Filter Depth 

P 4 2 0 4  

ANIN1FILTT2 

Analog Input 1 MSQ 1st 2nd Deriv 

P 4 2 0 5  

ANIN1FILTVELFF 

Analog Input 1 MSQ 1st Deriv FF 

P 4 2 0 6  

ANIN1LPFHZ 

Analog Input 1 Filter 

P 4 2 0 7  

ANIN1OFFSET 

Analog Input 1 Offset 

P 4 2 0 8  

ANIN2DB 

Analog Input 2 Deadband 

P 4 2 0 9  

ANIN2ISCALE 

Analog Input 2 Current Scaling 

P 4 2 1 0  

ANIN2LPFHZ 

Analog Input 2 Filter 

P 4 2 1 1  

ANIN2MODE 

Analog Input 2 Mode 

P 4 2 1 2  

ANIN2OFFSET 

Analog Input 2 Offset 

P 4 2 1 3  

ANIN2USER 

Analog Input 2 Voltage User Units 

P 4 2 1 4  

ANIN2USERDEN 

ANIN2USER Conversion Denominator 

P 4 2 1 5  

ANIN2USERNUM 

ANIN2USER Conversion Numerator 

P 4 2 1 6  

ANIN2USEROFFSET 

ANIN2USER Conversion Offset 

P 4 2 1 7  

ANIN2ZERO 

Analog Input 2 Zero Command 

P 4 2 1 8  

ANOUT 

Analog Output Value  

P 4 2 1 9  

ANOUTCMD 

Analog Output Command 

P 4 2 2 0  

ANOUTISCALE 

Analog Output Current Scaling 

P 4 2 2 1  

ANOUTLIM 

Analog Output Voltage Limit 

P 4 2 2 2  

ANOUTMODE

 

Analog Output Mode 

P 4 2 2 3  

ANOUTVSCALE

 

Analog Output Velocity Scaling 

P 4 2 2 4  

Содержание CDHD2

Страница 1: ...CDHD2 Servo Drive Operator Panel HMI Revision 1 0 Firmware Version 2 15 x...

Страница 2: ......

Страница 3: ...x Motion Control Ltd reserves the right to change the specifications of the product described in this manual without notice at any time Trademarks All marks in this manual are the property of their re...

Страница 4: ...CDHD2 4 Operator Panel HMI...

Страница 5: ...7 2 Operator Panel Parameter Mode____________________________________________ 12 3 Operator Panel Command Mode____________________________________________ 23 4 Operator Panel Monitoring Mode__________...

Страница 6: ...CDHD2 6 Operator Panel HMI...

Страница 7: ...ates and mode are not automatically displayed in the other Changes made from the panel might not appear in a ServoStudio task screen until the screen in refreshed exited and reopened When COMMODE 1 is...

Страница 8: ...r Press continuously Quickly scrolls through ascending parameter indices Speed of scrolling increases the longer the key is pressed Value Increases value by one increment Down Parameter Press once Nav...

Страница 9: ...ng fault codes and system information Refer to Operator Panel Faults Info Mode The drive remembers the last selected setting or value in each mode If one or more faults occurs while in Status Commands...

Страница 10: ...on control using serial commands If COMMODE 1 Object 6061 P P 1 Profile Position mode P S 3 Profile Velocity mode P t 4 Profile Torque mode H H 6 Homing mode S P 8 Cyclic Synchronous Position mode S S...

Страница 11: ...Power Up During power up the digital display shows 5 dashes This code is also displayed when the Ember switch is activated which sets the drive to serial communication Boot Up mode Ember Mode During t...

Страница 12: ...sulting from parameter manipulation are indicated by E followed by a two or three digit error code Refer to Error Messages in the CDHD2 User Manual If CONFIG is required after a parameter value is ent...

Страница 13: ...string First string integers up to 99999 Second string numerals in values up to 9 999 999 xxx Third string numerals in values up to 999 999 999 999 xxx Fourth string numerals in values up to 99 999 9...

Страница 14: ...rive Operation Mode P 0 0 0 1 GEARMODE Gearing Operation Mode P 0 0 0 2 ADDR Drive Communication Address P 0 0 0 3 XENCRES External Encoder Resolution P 0 0 0 4 GEARIN Gear Ratio Numerator P 0 0 0 5 G...

Страница 15: ...GAIN HD Maximum Adaptive Gain P 1 0 1 2 NLNOTCHCENTER HD Current Filter Notch Center P 1 0 1 3 NLNOTCHBW HD Current Filter Notch Bandwidth P 1 0 1 4 NLNOTCH2CENTER HD Current Filter 2nd Notch Center P...

Страница 16: ...VFR Position Velocity Feedforward P 1 2 1 3 KPAFRC Position Acc FF to Current Loop P 1 2 1 4 KPAFRV Position Acceleration Feedforward P 1 2 1 5 Current Loop Gains Starting at index 1300 KCP Current KP...

Страница 17: ...P 2 0 0 8 HALLSINV Hall Signals Inversion P 2 0 0 9 HALLSTYPE Hall Signals Type P 2 0 1 0 PHASEFINDMODE Phase Find Mode P 2 0 1 1 PHASEFINDI Phase Find Current P 2 0 1 2 PHASEFINDTIME Phase Find Dura...

Страница 18: ...0 0 2 MIPEAK Motor Peak Current P 3 0 0 3 MSPEED Motor Maximum Speed P 3 0 0 4 MPOLES Motor Poles P 3 0 0 5 MPITCH Motor Pitch P 3 0 0 6 MKT Torque Constant P 3 0 0 7 MKF Torque Constant for Linear Mo...

Страница 19: ...NV 11 Input Inversion input 11 P 4 0 2 1 OUTMODE 1 Output Mode output 1 P 4 0 2 2 OUTMODE 2 Output Mode output 2 P 4 0 2 3 OUTMODE 3 Output Mode output 3 P 4 0 2 4 OUTMODE 4 Output Mode output 4 P 4 0...

Страница 20: ...1 MSQ Filter P 4 2 0 3 ANIN1FILTT1 Analog Input 1 MSQ Filter Depth P 4 2 0 4 ANIN1FILTT2 Analog Input 1 MSQ 1st 2nd Deriv P 4 2 0 5 ANIN1FILTVELFF Analog Input 1 MSQ 1st Deriv FF P 4 2 0 6 ANIN1LPFHZ...

Страница 21: ...Gear Motor Shaft Scaling P 6 0 0 7 FBITIDX Fieldbus Interpolation Time Index P 6 0 0 8 FBITPRD Fieldbus Interpolation Time P 6 0 0 9 FBPLIGNORE Fieldbus Ignore Packet Loss Fault P 6 0 1 0 FBSCALE Fie...

Страница 22: ...2 0 8 Faults Modes and Thresholds Starting at index 7300 UVMODE Under Voltage Mode P 7 3 0 0 UVRECOVER Under Voltage Recovery Mode P 7 3 0 1 UVTHRESH Under Voltage Threshold P 7 3 0 2 UVTIME Under Vo...

Страница 23: ...s that follow When selecting entering a command 0 often flashes once in digit 1 This is standard behavior of the panel indicating a value can be entered Table 3 1 Command Codes Command VarCom Descript...

Страница 24: ...Generator Advanced for vertical applications drive based 10 External Motion Generator Express controller based 11 External Motion Generator Advanced controller based 12 External Motion Generator Adva...

Страница 25: ...0001 Press Shift Display n n s e t Press Long Shift Display Motor setup progress in number Done d o n e or an error code Clear Faults OK Code C 0 0 0 2 Command Clear Faults VarCom CLEARFAULTS Sequence...

Страница 26: ...Done 0 0 0 0 0 Note The ServoStudio toolbar status bar might not accurately reflect change in Enable Disable state Use the ST command in Terminal to verify Jog Code C 0 0 0 4 Command Jog VarCom J Not...

Страница 27: ...ng Shift Display joG8S jog motion stopped Press and hold Up key move motor at defined speed in positive direction Press and hold Down key to move motor at defined speed in negative direction Display j...

Страница 28: ...lti turn Reset VarCom MTTURNRESET Sequence Select C0007 Press Shift Display d o n e or an error code Restore Factory Settings Code C 0 0 0 8 Command Restore Factory Settings VarCom FACTORYRESTORE Sequ...

Страница 29: ...rror code Move Absolute Distance Code C 0 0 1 0 Command Move Absolute distance VarCom MOVEABS distance velocity Sets the distance argument Command uses velocity value set by JOGSPD1 Sequence Make sure...

Страница 30: ...Set a value of 2 revolutions Press Long Shift Display i n c n n during movement Display d o n e or an error code Note value of movement revolution counts degrees Sets distance for movement Speed is se...

Страница 31: ...splay P h a S e Press Shift Display Flashing 0 in digit 1 Press Long Shift Display d o n e or an error code Sine Cosine Calibration Code C 0 0 1 4 Command Sine Cosine Calibration VarCom SININIT Sequen...

Страница 32: ...Command VarCom Description Code V Actual speed in rpm d 0 0 0 0 PFB Actual position in degrees d 0 0 0 1 PFB Actual position in revolutions d 0 0 0 2 I Current in amperes d 0 0 0 3 IN Digital inputs 1...

Страница 33: ...0 0 0 2 0 negative motion 20 rpm Actual Position degrees Code d 0 0 0 1 Command Actual Position in degrees Description Shows the actual position of the motor as measured by the primary feedback in deg...

Страница 34: ...its 4 3 2 integer value digit 1 decimal value DP1 is lit If number of revolutions 100 digits 4 3 integer value digits 2 1 decimal value DP2 and DP1 are lit If number of revolutions 10 digit 4 integer...

Страница 35: ...sly 0 0 1 7 8 0 0 1 8 8 0 0 1 9 2 0 0 2 0 4 Digital Inputs 1 through 10 Code d 0 0 0 4 Command Digital Inputs State Description Indicates the state of digital inputs 1 through 10 Double height line on...

Страница 36: ...ss d0005 Press Shift Examples Digital input 11 is on Digital input 11 is off Digital Outputs 1 through 7 Code d 0 0 0 6 Command Digital Outputs State Description Indicates the state of digital outputs...

Страница 37: ...ption Object 6040h VarCom Not Applicable Sequence Press d0008 Press Shift Display h 0 0 0 0 for example Analog Input 1 Value Code d 0 0 0 9 Command Analog Input 1 Value Description Shows the value of...

Страница 38: ...nal counts Code d 0 0 1 1 Command Hardware Position External Description Shows the position as measured by an external feedback device in counts VarCom HWPEXT Sequence Press d0011 Press Shift Display...

Страница 39: ...es are displayed as a string in digits 4 3 2 and 1 as needed and do not flash If a fault remains in effect and a different display mode is selected the fault code characters will be displayed sequenti...

Страница 40: ...Press Up Display Fe Note Since the same fault may have been triggered multiple times you may need to press the Up or Down key a number of times before the code changes Alternately press and hold the...

Страница 41: ...nel HMI 41 FPGA Version Code F 0 0 0 2 Command Firmware Version VarCom VER Example FPGA Version 4 08 March 16 2017 Sequence Select F0002 Press Shift Display Press Shift Display Press Shift Display Pre...

Страница 42: ...ess Up Display L6 Notes When displayed in Status mode multi character warning codes are displayed in sequence in digit 4 only When displayed in Faults Info mode multi character codes are displayed as...

Страница 43: ......

Страница 44: ...CDHD2 Servo Drive Operator Panel HMI Servotronix 21C Yagia Kapayim St POB 3919 Petach Tikva 49130 Israel Tel 972 3 927 3800 info servotronix com www servotronix com...

Отзывы: