30
Operator Panel (HMI)
Move Incremental - Distance
Code
C 0 0 1 1
Command
Move Incremental - distance
VarCom
MOVEINC {distance} {velocity}
Sets the distance argument. Command uses velocity value set by JOGSPD1.
Sequence
Select: C0011
Display:
i n c n n
Press:
Long Shift
Display: flashing
0
Press:
(for example) Set a value of 2 (revolutions)
Press:
Long Shift
Display:
i n c n n
(during movement)
Display:
d o n e
(or an error code)
Note value of movement = revolution, counts, degrees
Sets distance for movement. Speed is set according JOGSPD1
Home
Code
C 0 0 1 2
Command
Home
VarCom
HOMECMD
Sequence
Select: C0012
Display:
h o n n e
Press:
Shift
Display: Flashing
0 .
in digit 1
Press:
Set the value of a homing type
Press:
Long Shift
Press:
Long Shift
Display: (indicates homing progress in a % number)
Display:
d o n e
(or an error code)