CDHD2
34
Operator Panel (HMI)
Actual Position (rev)
Code
d 0 0 0 2
Command
Actual Position, in revolutions
Description
Shows the actual position of the motor, as measured by the primary
feedback, in revolutions.
If the position is a negative value, DP5 is lit.
VarCom
PFB
Sequence
Select: d0002
Press:
Shift
Start motion.
If number of revolutions = 1000 – 9999:
digits 4 3 2 1 = integer value
If number of revolutions <1000:
digits 4 3 2 = integer value,
digit 1 = decimal value
DP1 is lit
If number of revolutions <100
digits 4 3 = integer value
digits 2 1 = decimal value
DP2 and DP1 are lit
If number of revolutions <10
digit 4 = integer value
digit 3 2 1 = decimal value
DP3, DP2 and DP1 are lit
If number of revolutions > 10,000, press
Shift
to view the next string.
Examples
Examples of display:
If position = 00.000 to 99.999:
String 1:
7 8 . 1 2 3 .
78.123 revolutions
9 7 . 3 4 5
97.345 revolutions
If position = 100.000 to 999.999:
String 1:
0 1 . 7 8 9 .
= 101.789 revolutions
0 4 . 3 6 7 .
= 104.367 revolutions
Press Shift
String 2:
0 0 0 0 . 1 .
= 101.789
0 0 0 0 . 1 .
= 104.367