MVG400 Installation Guide
Connecting Devices to the MVG400
19
Figure 18: Connecting sensors to the ADAM-4051 module
3. Connect the ADAM-4051 module to the ADAM-4520 isolated converter as follows (see figure 20, page 21):
Connect this connector on
the ADAM-4051
To this connector on the
ADAM-4520
(Y) Data+
Data+
(G) Data-
Data-
(R) +Vs
(R)+Vs
(B) GND
(B)GND
4. Connect the ADAM-4520 isolated converter to the
RS232/485
connector on the rear panel of the MVG400
unit in one of the following ways:
•
•
•
If you are not connecting any RS485 PTZ controllers to the unit, using the 9-pin flat ribbon cable, connect
the RS232 connector of the ADAM-4520 converter directly into the
RS232/485
connector.
•
•
•
If you are also connecting one or more RS485 PTZ controllers to the unit, using the 9-pin flat ribbon
cable, connect the RS232 connector of the ADAM-4520 converter into the RS232 connector of the
RS232/485 adapter supplied with the unit. Connect the PTZ controllers to the adapter as explained under
Connecting PTZ Controllers
, page 15. Then plug the adapter into the
RS232/485
connector on the unit.
D GND
Connect sensor ground
wires to this connector
D1 0
through
D1 10
Connect positive (+) sensor wires
to these connectors
D1 11
through
D1 15
Connect positive (+) sensor
wires to these connectors
D GND
Connect sensor ground
wires to this connector