DA
L
19
65
Pag. 6/18
Fig. 9
Fig. 8
MOTOR INSTALLATION
ON LEFT GATE WING
Fig. 10
Fig. 11
Fig. 12
Fig. 13
!!
Fig. 14
Fig. 15
8- Level the motor and tighten all screws and bolts
fully down. Fig. 8.
9- With the aid of a 17 mm wrench, turn the half-nut
on the mobile pin through half a turn to release
the motors. Fig. 9.
Check that movement is smooth. Return the
half nut of the mobile pin to the original
position. Close the gate: the motor blocks
when the gate reaches the closing end stop.
FINAL INSTALLATION
10- Remove the motor from the brackets. Weld the
front bracket in its final position. Fix the rear
bracket in its final position. Fig. 10.
11- Refit the motor.
12- Mount the lever release mechanism, as shown in
fig. 11. Remove the blank-out disk on the right
(marked internally with D) for the right leaf, and
remove the blank-out disk on the left (marked
internally with S) for the left leaf. In the hole,
insert the key block with protection cover.
Secure the hook-shaped pawl by means of the
relative nut onto the square pin of the key block.
Close the half nut of the mobile pin between the
two half-housings and secure by means of the
relative screws.
MOVING THE GATE MANUALLY IN THE EVENT
OF A POWER FAILURE
-
Use the key and release lever as shown in fig.
12.
-
Keeping the mobile pin released by means of the
release lever, open manually - Fig.13 -.
-
To restore the gate block, simply return the
release lever and gate to the positions prior to
release, pushing the gate until it engages -
Fig.14 -.
-
Return the key to the initial position to remove -
Fig. 15.
MOTOR INSTALLATION
ON RIGHT GATE WING
K
IT
/3
0
-3
9
F
I
E