With the control unit powered and the gate closed, press the A (SET) key once to enter the programming mode.
The DL10 LED starts flashing to indicate that the control unit is in the programming mode.
While the leaf is opening, set the motor power by means of the potentiometer POWER.
WARNING: - If the POWER potentiometer is set too low, the gate may not open. We
recommend setting POWER starting from the
MAXIMUM
value and gradually
moving down to the minimum value.
- The considerable differences in temperature between summer and winter can
cause differing rates of expansion in all materials, including those used in the
building of our motors. That is why we recommend you check the impact force
setting at the start of winter and summer.
WARNING:
-
If one or more parameters are altered, programming must be repeated from
the beginning.
-
In the programming procedure, deceleration has only been set in the
closing phase, but is implemented also during the opening phase.
Press the key C (WORK) once to start the opening phase of motor M1.
When the leaf reaches the opening stop, let a few seconds pass (max. 3-4s ) and then press key C (WORK)
once. Motor M1 is shut down.
With the leaf completely open and motor not powered, press the key C (WORK) once to start the closing
phase.
At the point in which motor M1 should start deceleration (at least 50cm before the stop is recommended) press
the key C (WORK). Motor M1 slows down.
WARNING: skip this point if deceleration is disabled (DIP2 SW2 ON)
When the leaf reaches the closing stop, let at least 5 seconds pass and then press key C (WORK) once. Motor
M1 is shut down and the control unit automatically exits the programming phase and is ready for normal
operation.
GATE OPEN PAUSE TIME PROGRAMMING (AUTOMATIC RECLOSURE)
With the control unit powered and the gate closed, press the A (SET) key once to enter the programming
mode. The DL10 LED will start flashing, indicating that the control unit has entered the programming
stage.
Press the key B (BREAK) once, keeping it pressed until the flashing light comes on; the control unit will
start the gate open pause count, which is indicated by the light flashing intermittently.
Once the desired time has lapsed, press the key B (BREAK) again; the control unit will automatically store
the amount of time between the two times the key B (BREAK) was pressed. It then quits the programming
phase and switches to standard operation mode.
If the key B (BREAK) is not pressed a second time within 120s, the control unit quits the programming,
memorising the maximum time as 120s.
ACTIVATING AUTOMATIC RECLOSURE (max time settable: 120s)
Press the key B (BREAK) and keep it pressed until the DL10 LED switches off.
The control unit quits the programming phase and switches to standard operation mode.
This operation deactivates the automatic reclosure function.
DEACTIVATING AUTOMATIC RECLOSURE
With the control unit powered and the gate closed, press the A (SET) key once to enter the programming
mode. The DL10 LED will start flashing, indicating that the control unit has entered the programming
stage.
WORK AND DECELERATION TIME PROGRAMMING FOR SINGLE LEAF GATES (DIP1 SW1 ON)
SIN
CE
1
96
5
K
IT
/3
0
-3
9
F
I
E