background image

Sentry Xpress 5 Cone-Fire / Ramp-Hold

30

Do not leave your kiln unattended during operation.

Preset Cone-Fire Programs - °F

These are the firing schedules programmed in Cone-Fire mode. To customize a schedule, write down your

changes. Then load your new schedule into Ramp-Hold.

Low Fire Cones °F

Segment 1

Segment 2

Cone

Rate 1 Temp. 1

Rate 2 Temp. 2

022

396

979

108

1087

021

396

1004

108

1112

020

396

1051

108

1159

019

396

1144

108

1252

018

396

1211

108

1319

017

396

1252

108

1360

016

396

1314

108

1422

015

396

1348

108

1456

014

396

1377

108

1485

013

396

1431

108

1539

012

396

1474

108

1582

011

396

1499

108

1607

Medium Fire Cones °F

Segment 1

Segment 2

Segment 3

Segment 4

Cone

Rate 1 Temp. 1

Rate 2 Temp. 2

Rate 3 Temp. 3

Rate 4 Temp. 4

010

324

1022

153

1112

180

1549

108

1657

09

324

1022

153

1112

180

1580

108

1688

08

324

1022

153

1112

180

1620

108

1728

07

324

1022

153

1112

180

1681

108

1789

06

324

1022

153

1112

180

1720

108

1828

05

324

1022

153

1112

180

1780

108

1888

04

324

1022

153

1112

180

1837

108

1945

03

324

1022

153

1112

180

1879

108

1987

02

324

1022

153

1112

180

1908

108

2016

01

324

1022

153

1112

180

1938

108

2046

High Fire Cones °F

Segment 1

Segment 2

Segment 3

Segment 4

Cone

Rate 1 Temp. 1

Rate 2 Temp. 2

Rate 3 Temp. 3

Rate 4 Temp. 4

1

324

1022

153

1112

162

1863

108

2079

2

324

1022

153

1112

162

1872

108

2088

3

324

1022

153

1112

162

1890

108

2106

4

324

1022

153

1112

162

1908

108

2124

5

324

1022

153

1112

162

1951

108

2167

6

324

1022

153

1112

162

2016

108

2232

7

324

1022

153

1112

162

2046

108

2262

8

324

1022

153

1112

162

2064

108

2280

9

324

1022

153

1112

162

2084

108

2300

10

324

1022

153

1112

162

2129

108

2345

Содержание Xpress 5.0

Страница 1: ...21 AOP1 For kilns with the optional AOP switch box electrical outlet p22 ELEC Check circuit board tem perature useful in hot weather p22 EXIT Press Start Stop to return to IDLE OPT3 Press Start Stop t...

Страница 2: ...if you hear a clicking noise during operation Mechanical relays click as they turn theheatingelementsonandoff Thisisnormal Itisalsonormalforthetemperaturetofluctuate up and down as the kiln heats up P...

Страница 3: ...or Glazes 17 General Options DELA Delay the Firing for Later 17 TC Choose Thermocouple Type 18 ALAR Temperature Alarm 18 Setting the Alarm From IDLE 18 Setting the Alarm During a Firing 18 DIAG Diagno...

Страница 4: ...s the controller will interpret a power interruption as a power failure and turn the kiln back on when you reconnect the power G Place the kiln on the stand recommended by the manufacturer When a kiln...

Страница 5: ...hermocouple Keep an extra thermocou ple on hand especially if you fire hotter than 2000 F 1093 C If you are using a separate portable controller you will need to install the thermocouple on the kiln S...

Страница 6: ...ower failed during a firing and the kiln tem perature was below 212 F 100 C when the power came back on PF 3 The power failed during a firing and the tempera ture dropped more than 72 F 40 C by the ti...

Страница 7: ...amp Hold Preventing an Overfire Even though a digital controller turns off the kiln auto matically you should monitor the kiln during firing This is to prevent a possible overfire 1 Remain nearby whil...

Страница 8: ...compare one firing to the next and alert you when something is wrong For example if the wit ness cone bends farther and farther with each consecutive firing this may indicate thermocouple temperature...

Страница 9: ...programmed into Cone Fire slow down during the last 216 F 120 C two hours to produce better density in the ware How to Interpret the Bending of a Pyrometric Cone The cones illustrated here are called...

Страница 10: ...me left in Hold To figure hold time for the next firing subtract time left in Hold from the total hold time entered Sentry Xpress 5 Cone Fire Ramp Hold 10 Do not leave your kiln unattended during oper...

Страница 11: ...y kiln is taking too long to fire 9 hours to cone 6 I want the kiln to fire in 4 hours Answer 9 hours is the firing time programmed into the Cone Fire mode at fast speed The easiest way to go faster i...

Страница 12: ...om your supplier The heating rate also varies depending on the thickness of the material Note Some brands of controllers fire to a temper ature in a given length of time If you would prefer to program...

Страница 13: ...is not in use 13 Ramp Hold Programming Instructions You have up to 20 segments available in Ramp Hold Zero outsegmentsthatyoudon tneed See step 9 below Lock Fan and Delay can each be turned on or off...

Страница 14: ...rature indefinitely until you press the Start Stop key Ceramics Watch the pyrometric witness cones through a peephole during hold Press the Start Stop key when the correct witness cone bends noting ho...

Страница 15: ...ng from the first seg ment that matches the current kiln temperature Chapter4 Customize Your Controller with Options In this chapter you will learn to G Activate slow cooling in Cone Fire G Check the...

Страница 16: ...s Then press Start Stop If you don t want to change the hold time after all leave the setting alone and press Start Stop Change the Target Temperature of the Current Segment 1 During a Cone Fire or Ra...

Страница 17: ...g feature It will appear as the COOL prompt during Cone Fire programming But first you have to turn on Slow Cooling in options If you don t turn on the option the Slow Cooling prompt will remain hidde...

Страница 18: ...the glass before the expected fusing or slumping temperature You can see the glass through a kiln window You can enter only one alarm temperature at a time However after the alarm beeps you can set t...

Страница 19: ...ay The controller operates in your choice of Fahrenheit or Celsius temperature In C display a lighted dot appears in the lower right In F it disappears To switch from F to C or vice versa 1 From IDLE...

Страница 20: ...Stop key IDLE will appear 4 From IDLE press the Up Arrow repeatedly un til TCOS appears 5 Press Start Stop O or a Thermocouple Off set will appear 6 Using the arrow keys enter the new offset Press Sta...

Страница 21: ...o such as when the lid is vented or a bead door is open when you load a bead rod CAUTION The High Temperature Deviation HTDE alarm shuts off the kiln to prevent an overfire On controllers with pre 18D...

Страница 22: ...tions 2 Whenyousee AOP1 press theStart Stopkey 3 Use the arrow keys to select one of the above op tions Then press Start Stop ELEC Electronics Temperature Check the Circuit Board Temperature High temp...

Страница 23: ...ou fire your kiln during off peak periods 1 From IDLE or while firing press the Up Arrow repeatedly until CENT appears Note With each Up Arrow key press you will see the next option When you see EXIT...

Страница 24: ...ess Start Stop to return to IDLE The software ver sion can be changed only at the factory CFG Configuration Code 1 From IDLE or while firing press the Up Arrow repeatedly until CFG appears Note With e...

Страница 25: ...H alarm for that particular segment LTDE Low Temperature Deviation I During a cooling down ramp or a hold the temperature is below the set point temperature by more than the de viation setting See Tem...

Страница 26: ...rogrammed temperature I During a cooling down segment the temperature is 100 F 56 C above thesegment s startingtemperature I A fast rate caused the controller to overshoot the target temperature I A r...

Страница 27: ...rts a firing after a power failure the display will show the following I PF 1 PF 2 or PF 3 I Total firing time before power failed I Temperature at the time of power failure I Current kiln temperature...

Страница 28: ...is too hot so the kiln shut off F C Change F C 19 Choose between operation in degrees F or degrees C Message Definition Page Reference F 1 or C 1 Target Temperature 13 This prompt which appears in Ram...

Страница 29: ...s a safety precaution If you had a S Type thermocouple and Reset selected K Type your kiln would overfire On the other hand if you had a K Type thermo couple S Type selected would underfire your kiln...

Страница 30: ...3 Rate 4 Temp 4 010 324 1022 153 1112 180 1549 108 1657 09 324 1022 153 1112 180 1580 108 1688 08 324 1022 153 1112 180 1620 108 1728 07 324 1022 153 1112 180 1681 108 1789 06 324 1022 153 1112 180 17...

Страница 31: ...2 Rate 3 Temp 3 Rate 4 Temp 4 010 180 550 85 600 100 843 60 903 09 180 550 85 600 100 860 60 920 08 180 550 85 600 100 882 60 942 07 180 550 85 600 100 916 60 976 06 180 550 85 600 100 938 60 998 05...

Страница 32: ...range 8 2212 2280 2320 Yellow 9 2235 2300 2336 White 10 2284 2345 2381 Pink Rate of temperature increase during last 90 120 minutes of firing Tables by courtesy of the Edward Orton Jr Ceramic Foundati...

Страница 33: ...an On Off User Program ______ Date_______________________________ Type of firing Firing results Recommendations for the next firing of this type RA1 1 Hd1 RA2 2 Hd2 RA3 3 Hd3 RA4 4 Hd4 RA5 5 Hd5 RA6 6...

Страница 34: ...e pyrometric cone placed on a kiln shelf beside the ware being fired O Overfire When a kiln fires hotter than intended Some kilns cannot overfire They don t get hot enough Overshoot The temperature ha...

Страница 35: ...te Start Stop F 1 Ready to enter a firing temperature Up Down Arrows 0200 Sample firing rate Start Stop HD 1 Ready to enter a hold time if any Up Down Arrows 00 00 Enter hold time 00 00 no hold time R...

Страница 36: ...Stop HOLD Ready to enter a hold time Up Down Arrows 00 20 Sample Enter hold hrs mins Start Stop COOL Ready to enter a cooling rate Up Down Arrows 0200 Sample cooling rate Start Stop LOCK Do you want...