background image

Operation Remarks

  Thermocouple:   

Activate  the  functions  just  by 

                               connecting   to  the   connector  
                               and  switch  to   TC   function.

  E-smart: 

1. In Emissivity mode, push the    button 

                      to enter the E-smart function.
                  2. Contact    the   target    surface   with 
                       thermocouple.
                  3. Point   the     target   with   infrared 
                      thermometer and push the measure 
                      trigger till  the buzzer beep.
                      The    cross-reference   Emissivity 
                      value will be memorized in the unit.
                  4. Press   the “

”   button    to  leave  

                      the  E-smart  function.
  

CIS: 

The color of backlight   will change when the 

            target temperature exceeds the setting point 
            of alarm temperature.
  

Memory:   

Activate the record function  by push 

                    the  “M” button.   To   delete   all   the  
                    records, press up or  down  button to 
                    DATA 0  and  press  “M” button.
  

Lock: 

Push the     button to continuously measure

            and display the temperature without pull the 
            measuring  trigger.
  

Function: 

The above functions can be activated 

                    always   in   any  step  of   operations   
                    mode in flow-chart.
  

Scan/Hold:

  In SCAN mode, the LCD displays both   

                       the current  temperature  in  Celsius 
                       or Fahrenheit. The unit will HOLD the
                       last reading  for 6 seconds  after  the 
                       trigger is released.
                       When the battery is low, the battery  
                       icon  shows and   the   unit  will 
                       continue to function.
  

Data:

 While DATA# flashes on  the  left  button ,

Dis

            the value on the Main Temperature 

play 

            can be recorded in “#” log. Simply press 
            “M” button.

9

 

 

Содержание Hybrid ST-643

Страница 1: ...RED THERMOMETER INFRARED THERMOMETER Intelligent Infrared Thermometer with Emissivity Smart and Color Identification Signal INFRARED THERMOMETER INFRARED THERMOMETER RoHS COMPLIANT H brid y H brid y 3 ST 643 ...

Страница 2: ......

Страница 3: ...Instruction Manual Version 01 07 NOV Hybrid Hybrid Infrared Thermometer RoHS COMPLIANT ...

Страница 4: ......

Страница 5: ...1 Electronic trigger lock function ...

Страница 6: ...2 ...

Страница 7: ...nt for measurement control and laboratory use IEC61000 4 2 Electrostatic discharge immunity test IEC61000 4 3 Radiated radio frequency Electromagnetic field immunity test IEC61000 4 8 Power frequency magnetic field immunity test ...

Страница 8: ...may not be disposed of with the trash It promotes the re use recycling and other forms of recovery of used materials and components and to improve the environmental performance of all operators manufacturers traders treatment facilities involved in the life cycle of products Dispose of the product appropriately in accordance with the regulations in force in your country 4 ...

Страница 9: ... F 9V Battery Instruction manual Carrying case Repeatability Resolution Response Time Emissivity Switchable LCD Backlight Auto Power Off Laser Sight Switchable Dimensions Weight E Smart Operation Temp Thermocouple K Type CIS 1 C 2 F 0 1 C 0 1 F 500 ms Automatically after approx 6 sec 180x130x40mm 7 09 x5 12 x1 57 0 50 C 32 122 F 10 95 RH YES YES YES YES Adjustable 0 1 1 0 YES Thermocouple Range 20...

Страница 10: ...4 Operations of Instrument 4 1 Quick Start 4 2 Unit Diagram 6 ...

Страница 11: ...Primary Display Max Min Avg Secondary Display Lock Key Up Button Function Key Low Battery Laser Buzzer On Off Data Log Thermocouple Emissivity High Low Alarm Memory Key Down Button 1 2 3 4 5 6 8 9 10 11 12 7 13 14 15 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 ...

Страница 12: ...EMS 8 ...

Страница 13: ...arm temperature Memory Activate the record function by push the M button To delete all the records press up or down button to DATA 0 and press M button Lock Push the button to continuously measure and display the temperature without pull the measuring trigger Function The above functions can be activated always in any step of operations mode in flow chart Scan Hold In SCAN mode the LCD displays bo...

Страница 14: ...10 ...

Страница 15: ...s of the unit The FOV is the ratio of the distance from the target to the target diameter The smaller the target the closer you should be to it When the target diameter is small it is important to bring the thermometer closer to the target to insure that only the target is measured excluding the surroundings 11 5 Techniques of Infrared Thermometer 5 1 ...

Страница 16: ...n object at a given temperature to the energy emitted by a perfect radiator at the same temperature All values of emissivity fall between 0 0 and 1 0 6 Maintenance Cleaning the lens Blow off loose particles using clean compressed air Gently brush remaining debris way with a camel s hair brush Carefully wipe the surface with a moist cotton swab The wab may be moistened with water NOTE DO NOT use so...

Страница 17: ...ass hard rolled polished w lines 21 70 0 04 Iron galvanized bright 0 13 Iron plate completely 20 68 0 69 Rolled sheet steel 21 71 0 66 Oxidized iron 100 212 0 74 Wrought iron 21 70 0 94 Molten iron 1299 1399 3270 2550 0 29 Copper polished 21 117 70 242 0 02 Copper scraped shiny not mirrored 22 72 0 07 Copper Plate heavily oxidized 25 77 0 78 Enamel white fused on iron 19 66 0 9 Formica 27 81 0 94 ...

Страница 18: ...PA05 000064X 01 ...

Страница 19: ...ST 643 Version 01 07 NOV 3F No 122 Sec 1 Sanmin Road Ban Ciao Taipei 220 Taiwan R O C TEL 886 2 2956 8198 FAX 886 2 2956 7662 http www sentrytek com tw PA05 0000643 01 ...

Отзывы: