System Specifications 

 

Water pressure: 40 psi minimum 100 psi Maximum 

 

Water Temperature: 40°F to 110°F 

 

Electrical Requirements:  
 

Supply Voltage: 120V 

 

Supply Frequency: 60Hz 

 

Output Voltage: 12V AC 

 

Output Current: Maximum 3.0 Amps 

 

Water Meter: 
 

Pipe Size: 3/4”-1” 

 

Accuracy: ± 5% 

 

Minimum Flow : 0.25 GPM  

 

Control Valve to Tank Connection: 2.5”-8UN 

 

Control Valve Distributor Pipe Connection: 1” 

 

Circuit Board Memory: NonVolatile EEPROM (

E

lectrical 

E

rasable 

P

rogrammable 

R

ead 

O

nly 

M

emory) 

 

Compatible with the following typical concentrations of regenerant chemicals: Sodium Chloride, Potassium 

Chloride, Potassium Permangenate, Sodium Bisulfite, Chlorine and Chloramines 

 

 

Warnings 

 

The control valve and fittings are not designed to support the weight of the system or the 

plumbing. 

 

Do not use Vaseline, oils, other hydrocarbon lubricants or spray silicone anywhere. A 

silicone lubricant may be used on black O-rings. 

 

Hydrocarbons such as kerosene, benzene, gasoline, etc., may damage products that 

contain O-rings or plastic components. Exposure to such hydrocarbons may cause the 

products to leak. Do not use the product(s) contained in this document on water supplies 

that contain hydrocarbons such as kerosene, benzene, gasoline, etc. 

 

The water meter should not be used as the primary monitoring device for critical or health 

effect applications. 

 

Do not use pipe dope or other sealants on threads. Teflon tape is recommended to be 

used on all threads. Use of pipe dope may break down the plastics in the control valve. 

System Specifications and Warnings 

Содержание 960SM Series

Страница 1: ...Single Metered Water Softening System Owner s Manual Series 960SM...

Страница 2: ...ontents System Specifications and Warnings 3 Start Up Instructions 4 Series 960 Control Valve Programming 5 Manually Regenerating the Water Softener 8 Bypass Valve Operation 9 Troubleshooting the Cont...

Страница 3: ...ontrol valve and fittings are not designed to support the weight of the system or the plumbing Do not use Vaseline oils other hydrocarbon lubricants or spray silicone anywhere A silicone lubricant may...

Страница 4: ...n to advance the controller to the next cycle The softener is now in the Fast Rinse cycle Leave the unit in the Fast Rinse cycle for at least five minutes While the system is rinsing manually fill the...

Страница 5: ...5 Control Valve Programming Series 960 Control Valve Programming...

Страница 6: ...EXT and the UP Arrow buttons at the same time and hold for 3 seconds Step 2 Raw Water Hardness Adjust to the correct hardness by pressing the UP or DOWN arrow button Default setting 20 grains per gall...

Страница 7: ...time of day will flash indicating that it needs to be set Step 1 Press SET CLOCK Step 2 Current Time of Day Hours Adjust to the correct hour by pressing the UP or DOWN arrow button Press NEXT to go t...

Страница 8: ...the water you may want to manual regenerate the softener using the delayed regeneration method To initiate a delayed regeneration simply push the REGEN button one time Don t hold the button down REGE...

Страница 9: ...9 Bypass Valve Operation Normal Operation Bypass Operation Diagnostic Mode Shut Off Mode...

Страница 10: ...Connect Meter to three pin connection labeled METER on Circuit Board Remove and reconnect to ensure proper connection Restricted stalled Meter Turbine Remove Meter and check for rotation or foreign m...

Страница 11: ...place Damaged Seal and Spacer Stack Assembly Replace Seal and Spacer Stack Assembly Control valve body type and piston type mix matched Verify proper control valve body type and piston type match Foul...

Страница 12: ...12 OM A960SM Printed in the USA Version 160915 1...

Отзывы: