![Sentiotec CV 31 Скачать руководство пользователя страница 64](http://html.mh-extra.com/html/sentiotec/cv-31/cv-31_instructions-for-installation-and-use-manual_1244676064.webp)
WORLD OF WELLNESS
Instructions for use for the user
p. 30/34
11.3. Changing fuses
Note
Fig. 3
in the figures chapter.
1. Remove housing cover
5
according to “4.1. Installing the sauna control
unit” on page 9.
2. Carefully pull control panel
1
from the housing lower part
6
.
3. Replace fuse for the interior lighting (microfuse 5 x 20 T2.0 A/ 250 V)
9
,
or fuse for fan (sub-miniature fuse TR 5 – T 1.0 A/ 250V)
7
,
or fuse for the
electronics of the device
a
(microfuse 5 x20 T630 mA/ 250 V) A (
Fig. 3
).
4. Insert tabs
2
of the operating unit
1
into the two lateral holders
3
and
carefully press onto the housing lower part
6
to the stop position.
5. Place the housing cover
5
onto the housing lower part
6
, swivel downward
and press until it clicks audibly. Check the fit of the control unit.
11.4. Messages in the display
1. LL in the display
The following appears in display
5
:
LL
Interior temperature is below 10 °C.
WARNING!
Electric shock
Before opening the housing cover, disconnect all poles of the sauna
control unit and secure against reconnection.