![Sentiotec CV 31 Скачать руководство пользователя страница 49](http://html.mh-extra.com/html/sentiotec/cv-31/cv-31_instructions-for-installation-and-use-manual_1244676049.webp)
WORLD OF WELLNESS
EN
Installation instructions, only for experts
p. 15/34
e. Now disconnect one of the white wires for the heater sensor.
f. Switch on the sauna control unit.
►
A recurring warning tone sounds, “Err4” appears in the display.
►
The control unit switches off the heater.
g. Switch off the sauna control unit.
h. Reconnect the white wire for the heater sensor.
3. Check the phase circuit for sauna mode L1, L2, L3 is connected to U, V, W.
4. Check the phase circuit for evaporator mode L1, L2, L3 is connected to U,
V1, W.
5. Check the maximum permissible heating output of 3.5 kW per phase on the
sauna control unit.
6. When there is an optional power booster:
a. Check the control wires ST1, ST2 and ST3.
b. Check the maximum permissible heating output of 3 kW per phase on
the power booster S2-18.
c. Check the maximum permissible heating output of 7 kW per phase on
the power booster S2-30.