PRODUCT DESCRIPTION

The GTE fan speed controller automatically regulates the speed of single phase 
voltage controllable motors (230 VAC / 50—60 Hz) according to the measured 
temperature values. The maximum speed can be adjusted via an internal 
trimmer. The minimum speed and temperature setpoint can be adjusted via 
external potentiometers. There are two product versions: -DM with Modbus RTU 
communication and -DT with an integrated motor socket, power cable and a PT500 
temperature probe. The fan speed will increase as the measured temperature 
exceeds the setpoint temperature.

ARTICLE CODES

Code

Temperature range

PT500 temperature 

sensor included 

Schuko socket 

for simple motor 

connection 

Integrated 

power supply 

cable  

Modbus RTU

GTE21-60-DM

5—35 

º

C

no

no

no 

yes 

GTE21-60-DT

5—35 

º

C

yes

yes 

yes

no

GTE-1-60-DM

15—35 

º

C

no

no

no 

yes 

GTE-1-60-DT

15—35 

º

C

yes

yes 

yes

no

INTENDED AREA OF USE

 

Greenhouses and temperature controlled ventilation systems

 

For indoor use only

TECHNICAL DATA

 

Supply voltage: 230 VAC ± 10 %/ 50—60 Hz

 

Output load: max. 6 A

 

Potentiometer for minimum speed setting

 

Internal trimmer for maximum speed setting

 

Adjustable hysteresis and proportional range 

 

 

Potentiometer for temperature setpoint range: 5—35 °C or 15—35 °C, 
depending on the product version

 

 PT500 temperature probe input (pre-wired for the -DT version and separately 
available for the -DM version)

 

Modbus RTU communication (only in -DM version)

 

Schuko socket for motor connection (only in -DT version)

 

Euro plug for power supply (only in -DT version)

 

Pre-wired temperature sensor and supply cable (only in -DT version)

 

Enclosure: plastic R-ABS, V; grey colour (RAL 7035)

 

Protection standard: IP54 (according to EN 60529)

 

Storage temperature: -40—50 °C

 

Operating ambient conditions:

 

temperature: 0—40 °C

 

rel. humidity: <95 % rH (non-condensing)

 

Storage temperature: -40—50 °C

ELECTRONIC   
FAN SPEED CONTROLLER

GTEX1-60

Содержание GTEX1-60-DM

Страница 1: ...Mounting and operating instructions GTEX1 60 ELECTRONIC FAN SPEED CONTROLLER ...

Страница 2: ...ED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 WIRING AND CONNECTIONS 5 OPERATIONAL DIAGRAM 5 MOUNTING INSTRUCTIONS IN STEPS 6 VERIFICATION OF INSTALLATION INSTRUCTIONS 9 MODBUS REGISTERS MAPS 10 TRANSPORT AND STOCK KEEPING INFORMATION 11 WARRANTY INFORMATION AND RESTRICTIONS 11 MAINTENANCE 11 ELECTRONIC FAN SPEED CONTROLLER GTEX1 60 ...

Страница 3: ...sible avoid condensation All installations shall comply with local health and safety regulations and local electrical standards and approved codes This product can only be installed by an engineer or a technician who has expert knowledge of the product and safety precautions Avoid contacts with energised electrical parts always treat the product as if it is live Always disconnect the power supply ...

Страница 4: ...es yes no GTE 1 60 DM 15 35 ºC no no no yes GTE 1 60 DT 15 35 ºC yes yes yes no INTENDED AREA OF USE Greenhouses and temperature controlled ventilation systems For indoor use only TECHNICAL DATA Supply voltage 230 VAC 10 50 60 Hz Output load max 6 A Potentiometer for minimum speed setting Internal trimmer for maximum speed setting Adjustable hysteresis and proportional range Potentiometer for temp...

Страница 5: ...eutral L1 230 VAC not regulated output max 2 A GND T TEMP PT500 temperature sensor A RS485 signal A B RS485 signal B P5 Motor connection GTEX1 60 DT L Supply voltage 230 VAC 50 60 Hz mono phase 10 N Neutral PE Ground L1 230 VAC not regulated output max 2 A GND T TEMP PT500 temperature sensor Schuko socket Motor connection OPERATIONAL DIAGRAM Control curve 100 90 80 70 60 50 40 30 20 10 Min 5 15 C ...

Страница 6: ...ded in the set and factory connected Also the DT version has a Schuko socket to plug in the motor fan If your unit is DT please skip step 1 2 Fix the jumpers accordingly see Fig 2 Jumper positions below NOTE The DM version can be used both as a stand alone unit or in conjunction with a computer and operated by Sentera s 3SModbus software or the Sensistant configurator When used stand alone its jum...

Страница 7: ...e maximum speed trimmer to the desired value You can choose from the range 170 230 VAC The factory setting is 230 VAC 5 Optional setting The Network Bus Terminator NBT see Fig 5 NBT jumper used with Modbus RTU By default the NBT is disconnected Fig 5 NBT jumper NBT is connected NBT is disconnected factory pre set NOTE Connect the NBT only in the two most distant units on the network line Connect t...

Страница 8: ...nd the correct mounting position and unit mounting dimensions See Fig 6 Mounting dimensions and Fig 7 Mounting position Fig 6 Mounting dimensions Fig 7 Mounting position 140 102 140 97 140 204 Acceptable Not acceptable 4 Set the maximum speed trimmer to the desired value see Fig 8 Max speed trimmer You can choose from the range 170 230 VAC The factory setting is 230 VAC Fig 8 Max speed trimmer Vma...

Страница 9: ... power supply cable Euro standard Integrated cable with PT500 sensor 4 The connected motor will run at min speed 5 Adjust the TEMP potentiometer to temperature equal to the ambient temperature 6 The motor fan will run at min speed and speed up if the ambient temperature rises hold the temperature probe in your hands to check 7 Adjust the temperature potentiometer to the min position 5 C for GTE21 ...

Страница 10: ...0 DM 3003 5 HW version unsigned int Hardware version of the device Read only XXXX GTE21 60 DM GTE 1 60 DM 0x0210 0x0200 HW version 2 10 HW version 2 00 6 SW version unsigned int Software version of the device Read only XXXX GTE21 60 DM 0x0300 SW version 3 00 GTE 1 60 DM 0x0230 SW version 2 30 7 Operating mode unsigned int Mode of operation 0 1 0 0 1 Standalone mode Modbus mode 8 Output overwrite u...

Страница 11: ... any responsibilities The manufacturer bears no responsibility for any misprints or mistakes in this data ATTENTION Use only fuses of the type and rating specified above otherwise loss of warranty will ensue MAINTENANCE In normal conditions this product is maintenance free If soiled clean with a dry or dampish cloth In case of heavy pollution clean with a non aggressive product In these circumstan...

Отзывы: