Input/output configuration
FlexZone Product Guide
Page 83
Local control mode
In local control mode, the two Aux inputs are used to activate electronic self-tests (AUX1 = A-side,
AUX2 = B-side). To activate the self-test function, close a momentary switch across the input. You
must close the momentary switch for the time specified in the Filter Window. Leave the AUX inputs
open if you do not want to use the self-test function.
Remote control mode
In Remote control mode, the two Aux inputs serve as auxiliary device inputs to the host Security
Management System (SMS). The inputs are available for reporting the status of other security
devices. The processor reports any change of an input’s state to the SMS via the Silver Network
Manager.
includes the selectable Remote Control input wiring configurations, and
includes the selectable supervision resistor values.
Input option
UCM selection
Alarm relay Supervision
R1
R2
unsupervised
NO
---
---
---
single resistor
supervision
NO
cut
5.1 k
---
dual resistor
supervision
NO
cut & short
4.3 k
820
unsupervised
NC
---
---
---
single resistor
supervision
NC
short
5.1 k
---
dual resistor
supervision
NC
cut & short
5.1 k
820
Table 2: Selectable input configurations
R1 values (single resistor
supervision)
R1 values (double resistor
supervision)
R2 values (double resistor
supervision)
820
1.1 k
820
1 k
2.2 k
1.1 k
1.1 k
4.3 k
2.2 k
1.2 k
4.7 k
3.3 k
1.5 k
5.1 k
5.6 k
2.2 k
5.6 k
3.3 k
4.7 k
5.1 k
5.6 k
Table 3: Selectable resistor values