Installing the sensor cable
Page 48
FlexZone Product Guide
3. Make the splice connection.
Armored cable terminations
Armored sensor cable terminations use the standard termination kit (P/N G6KT0201) and are
protected by an armored metal shell (G6KT0300).
Figure 55: Making the splice connection
Note
Senstar strongly recommends the use of a conduit stripping tool to
prevent burrs and sharp protrusions at the cut edge of the conduit.
Use the supplied bushings to protect the cable at the armor strip point.
a. Feed each cable through one section of the shell.
b. Insert the center conductor into the lower terminal and
c. Connect the second sensor cable ensuring that shield
the shield into the upper terminal and tighten the
conductor.
meets shield and center conductor meets center
d. Secure the sensor cables to the splice PCB with four
cable ties. Keep the cable ties on the same side, and
at a 45º angle from the flat plane of the CCA.
center conductor
shield
screws (follow the screening on the PCB).
h. Raise the armored shell 15 cm (6 in.) above the cable
run and attach it to the fence horizontally with four cable
ties. For increased security, use stainless steel straps
e. Center the splice between the double cable guide bars
f. Snap the enclosure shut so that the two locking tabs
are latched in the slots, and the enclosure is closed
g. Rotate one half of the armored shell so both screw
and then press the sensor cables firmly into the guide
and locked with gel oozing out of the ends.
bars and the splice CCA into the gel.
or wire ties.
15 cm (6 in.)
drip loop
clamps are pointed toward the ground and fit the two
halves of the shell together with the enclosure
centered inside. Tighten the screw clamps.