background image

                                                                                           Sensorsoft Thermometer User’s Manual

 

 
The Sensorsoft device modular-jack connector uses the same UTP wire map as 10-BASE-T. It is 
therefore possible to use this type of cabling system for Sensorsoft devices. 
 
PIN-OUT OF THE MODULAR 8 POSITION JACK/PLUG ON A SENSORSOFT DEVICE  

Note:  Terminal No. 1 is the terminal to the extreme left as you face the cable opening, latch tab down. 

 

Terminal 

Function 

UTP wire color 

1 Receive 

Data  white-green 

2 Ground 

green 

3 Transmit 

Data  white-orange 

Power  +V 

blue 

5 Ground 

white-blue 

6 Ground 

orange 

7 Power 

+V 

white-brown 

8 Ground 

brown 

 
The following are specialized tools and parts needed to make good quality cables: 
 

Hand Tools: 

Tyco Crimping Tool P/N  1-231652-0 or 2-231652-1,  for modular plugs 
Tyco 8 position modular die set  P/N 853400-1 
Tyco Crimping Tool P/N  90312-1 or 90302-1, for subminiature D pin or socket contacts 
Tyco PROCRIMPER  P/N 58448-2, for subminiature D pin or socket contacts 
Tyco Insertion/Extraction Tool P/N 91285-1, for subminiature D connector contacts 

Materials: 

CP Technologies CAT5E UTP stranded, P/N E-207-4P-C5-LGY, 1000 ft, light gray, RoHS 

(4 pair, 8-#24 AWG wires, category 4 or better, 75 C) 

Tyco 8 position modular plug for round stranded wire cables,  P/N 5-554169-3 (CAT4) 
Tyco 8 position modular plug for round stranded wire cables,  P/N 5-557961-3 (CAT5) 
Tyco DB-9 receptacle subminiature D connector (crimp-snap-in), P/N 205203-1 or -3 
Tyco DB-25 receptacle subminiature D connector (crimp-snap-in), P/N 205207-1 or 207463-1 
Tyco socket crimp contact for subminiature D connectors, P/N 1-66504-0 
Tyco pin crimp contact for subminiature D connectors, P/N 1-66506-0 

 

16

Содержание ST6105C

Страница 1: ...r s Manual Models ST6105J ST6105C and ST6154J Manual P N 071 0014 Rev 18 February 21 2019 Copyright 1999 2019 Sensorsoft Corporation All rights reserved Sensorsoft and Soft Thermometer are trademarks...

Страница 2: ......

Страница 3: ...opriate measurement instruments for making comparisons 11 Correct method for making comparisons 12 What to do if you believe the Sensorsoft device is reading incorrectly 12 Making extension cables for...

Страница 4: ...Thermometer may be referred to as a thermometer device Soft Thermometer Sensorsoft device or SSD Sensorsoft Soft Device throughout the manual Glossary of Acronyms RWME Remote Watchman Enterprise softw...

Страница 5: ...equired CRC error detection detects transmission errors and improves reliability SSDP only Virtually unlimited cable lengths 1000 ft SSDP only Plug and go operation little or no user configuration req...

Страница 6: ...meter to come into contact with harsh chemicals or cleaning agents If the housing needs to be cleaned use a damp cloth or vacuum cleaner Use a Velcro fastener P N F1000 or F1001 to affix the Sensorsof...

Страница 7: ...er refer to its documentation for more details on the above Note the physical port number where you plugged the cable into your computer or device console server If the Sensorsoft Thermometer is being...

Страница 8: ...onductor Communications connector 8 position modular jack accepts 8 position plug RJ45 Power source Port powered RTS and DTR both asserted or via External DC power connector Power supply current drain...

Страница 9: ...rial Injection molded ABS thermoplastic Housing Color Light gray Sensor type Semiconductor Communications cable Integrated 6 m 20 ft colour matched cable with DB 9F female mini D SUB connector Power s...

Страница 10: ...ectronics Housing Temperature Operating Range 40 C to 60 C 40 F to 140 F Electronics Housing Humidity Operating Range 90 RH non condensing Communications connector 8 position modular jack accepts 8 po...

Страница 11: ...cantly better accuracy and resolution then the device under testing When a calibration check is performed on a Unit under Test with an instrument traceable to the National Standards Laboratory the Uni...

Страница 12: ...minutes for the Sensorsoft device and the traceable measurement instrument to acclimatize to the environment 4 Make sure you know how to get a live up to the second temperature reading from the Sensor...

Страница 13: ...d get jammed In this situation it makes sense to terminate the cables on site using hand crimp tools The following details will assist you in this process NOTE A C suffix Sensorsoft device has a built...

Страница 14: ...parts needed to make good quality extension cables Hand Tools Tyco Crimping Tool P N 90312 1 or 90302 1 for subminiature D pin or socket contacts Tyco PROCRIMPER P N 58448 2 for subminiature D pin or...

Страница 15: ...has a RJ45 jack connector It accepts a plug in cable This includes models ST6105J and ST6154J Figure 3 Illustrates a J suffix Sensorsoft device that accepts a cable with RJ 45 plug IMPORTANT A properl...

Страница 16: ...1 for modular plugs Tyco 8 position modular die set P N 853400 1 Tyco Crimping Tool P N 90312 1 or 90302 1 for subminiature D pin or socket contacts Tyco PROCRIMPER P N 58448 2 for subminiature D pin...

Страница 17: ...into the SSD M indicates male pin type connector F indicates female socket type connector Figure 5 The C2012A cable is used to connect a J suffix Sensorsoft device to multi port serial cards or devic...

Страница 18: ...commend keeping the cabling short 100 ft as the Simple Text Commands Interface does not support the built in CRC error detection Sensorsoft Device Monitoring NET Component for Windows This method invo...

Страница 19: ...nsorsoft device may ignore your commands can be due to data transmission CRC errors or improper power up delay during hot plugging Sending SSDP commands to the Sensorsoft device Each command packet yo...

Страница 20: ...01h 00h 00h 00h 00h 00h 47h 98h Send the following bytes to request a temperature reading in Celsius 0 5 C resolution C5h 0Ch 00h 01h 00h 00h 00h 00h 00h 01h 0Eh 49h Send the following bytes to reques...

Страница 21: ...nt that the previous host command was received and executed without errors The Sensorsoft device only acknowledges correctly received commands that have no CRC errors If the Sensorsoft device detects...

Страница 22: ...5 6 and 7 can be ignored they are not used Converting SSDP DATA byte s to temperature readings Recent Sensorsoft temperature measuring devices can output temperature readings in two different formats...

Страница 23: ...1111 FFFFh 25 C 11111111 11001110 FFCEh 40 C 11111111 10110000 FFB0h 55 C 11111111 10010010 FF92h Please note that the least significant temperature DATA byte is in terms of a 0 5 C The sign bit is du...

Страница 24: ...d strings The sequence of four strings begins at the 10th byte in the response packet To read the SSD s description count to the 10th byte in the ID response and extract the subsequent ASCII null term...

Страница 25: ...ser s Manual Sample ID response packet from a ST6105J Sensorsoft Thermometer Byte Contents 1 90h 2 4Fh 3 00h 4 9 01h 00h 00h 03h 03h 07h 10 Sensorsoft R Thermometer 00h Sensorsoft Corp 00h ST6105J 00h...

Страница 26: ...support to help you overcome your difficulties see web site address below Sensorsoft Corporation does not provide free support to those wishing to write their own software although this is available o...

Страница 27: ...n a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this guide may cause harmful interference to radio comm...

Отзывы: