FA 46 Vision Sensor GB - 068-14297 - 10.02.2011-05
Mounting and
operating instructions
53
2.2
Characteristics FA 46 301/305 Object detection
301
305
Number of Jobs
1
n
Position tracking
-
X
Number of detectors
n
n
Type of detectors
-
Pattern matching (X-, Y- Translation)
X
X
-
Contour matching (X-, Y translation and rotational position)
X
X
-
Grey threshold
X
X
-
Contrast
X
X
4 Signal outputs 0-24 V DC PNP, 2 inputs
X
X
Ethernet interface / data transmission
Setup only
X
RS 422 interface for data transmission
-
X
EtherNet/IP
-
X
Logic
One level Multilevel
Sensor monitoring with viewer, job upload, etc.
X
X
I/O extension with encoder control
-
X
Version with C-Mount
-
X
2.2.1
Sensor types
Sensor name
*1
min. operating distance/mm
*2
Field of view /mm x mm
Part no.
FA46-305-WCC-OBO6ES6
6
4 x 5
522-91151
FA46-305-WCC-OBO12ES6
22
6 x 8
522-91152
FA46-305-RCC-OBO6ES6
6
4 x 5
522-91153
FA46-305-RCC-OBO12ES6
22
6 x 8
522-91154
FA46-305-ICC-OBO6ES6
6
4 x 5
522-91175
FA46-305-ICC-OBO12ES6
22
6 x 8
522-91176
FA46-305-CC-OBOCSES6
*3, 4
C-Mount, dependent on lens
C-Mount, dependent on lens
522-91155
FA46-301-WCC-OBO6LS5
6
4 x 5
522-91171
FA46-301-WCC-OBO12LS5
22
6 x 8
522-91172
FA46-301-RCC-OBO6LS5
6
4 x 5
522-91173
FA46-301-RCC-OBO12LS5
22
6 x 8
522-91174
*1
Other types available on request
*2
For greater operating distances (from approx. 100 mm) external illumination may be necessary.
The typical focus range is operating distance ± 5%.
*3
When the C-Mount version of FA 46 is in use, a C-Mount lens with a 6.6 mm intermediate ring or a C-Mount protective case
is required (see accessories chapter 8.10).
*4
IR illumination is only possible with C-Mount sensors.