8.9
FAQs
How can I change the IP address set for the sensor?
Follow the steps described under “Network settings” and “Setting the FA 46 Vision Sensor’s IP address” in
chapter 3.3.
How can I just test connection to the FA 46 Vision Sensor?
Go into the start menu of the operating system, open “Execute” and enter the command “cmd”. A window then
opens, in which you should enter the command “ping”, followed by the set IP address:
For example: ping 192.168.100.100
If all connections are correctly connected, the sensor and PC address space is identical and the FA 46 Vision
Sensor is ready, the ping command receives a positive reply. If this does not occur, check your network configu
-
ration and consult your network administrator.
How can I avoid reflections (recognisable as light image zones)?
Install the FA 46 Vision Sensor at an angle to the optical axis and set the shutter manually. Improve illumination
of the object and avoid fluctuations in brightness, e.g. through ambient light.
I obtain grey value dispersions on the same object. The grey values at the edge of the illuminated zone vary
in appearance from image to image.
What can I do?
Set “Shutter einl./manuell“ in the field “parameters of active configuration” to manual and then adjust the slide
bar so that no fluctuations in brightness occur. A higher shutter value generally results in a slight overexposure
but provides a more constant result.
Reflections occur though a minimal change in alignment or position, e.g. an inscription sometimes appears
lighter, sometimes darker.
How can I obtain a constant image scene?
Install the FA 46 Vision Sensor at an angle of approx. 10° - 15° or select another position of the pattern frame
where reflections will not affect pattern detection.
8.10
Accessories
Description
Order type
Part no.
Dove tail mounting clamp FA 45
MK 45
543-11000
Mounting bracket FA 45
MA 45
543-11001
Mounting bracket FA 45 long
MA 45 L
543-11013
Rod mounting block FA 45
MB 45
543-11002
Mounting rod 20 cm FA 45
MST 45-20
543-11005
Mounting rod 30 cm FA 45
MST 45-30
543-11006
Mounting rod 40 cm FA 45
MST 45-40
543-11007
Mounting hinge FA 45
MG 45
543-11008
Mounting plate FA 45
MP 45
543-11003
Mounting link FA 45
MZ 45
543-11004
Connection cable, 2 m, straight connector, shielded
C L8FSK-2m-G-PUR
902-51708
Connection cable, 5 m, straight connector, shielded
C L8FSK-5m-G-PUR
902-51709
Connection cable, 10 m, straight connector, shielded
C L8FSK-10m-G-PUR
902-51710
Connection cable, 2 m, 90° connector, shielded
C L8FSK-2m-W-PUR
902-51711
Connection cable, 5 m, 90° connector, shielded
C L8FSK-5m-W-PUR
902-51712
Connection cable, 10 m, 90° connector, shielded
C L8FSK-10m-W-PUR
902-51713
Ethernet cable, 3 m, M12, 8 pin / RJ45, shielded, patch
CI L8FSK/RJ45S-3m-GG-PVC
902-51715
Ethernet cable, 3 m, M12, 8 pin / RJ45, shielded, cross-over
CI L8FSK/RJ45S-3m-GG-PVC-G 902-51736
Ethernet cable, 3 m, M12, straight connector, 4-pin, D coded/RJ45,
shielded (patch)
CI L4MGK/RJ45G-S-3m-PUR
902-51761
Ethernet cable, 3 m, M12, straight connector, 4-pin, D coded/RJ45,
shielded (cross-over)
CI L4MGK/RJ45G-GS-3m-PUR
902-51762
Ethernet cable, 5 m, M12, straight connector, 4-pin, D coded/RJ45,
shielded (patch)
CI L4MGK/RJ45G-S-5m-PUR
902-51763
Ethernet cable, 5 m, M12, straight connector, 4-pin, D coded/RJ45,
shielded (cross-over)
CI L4MGK/RJ45G-GS-5m-PUR
902-51764
Ethernet cable, 10 m, M12, straight connector, 4-pin, D-coded/
RJ45, shielded (patch)
CI L4MGK/RJ45G-S-10m-PUR
902-51765
Ethernet cable, 10 m, M12, straight connector, 4-pin, D-coded /
RJ45, shielded (cross-over)
CI L4MGK/RJ45G-GS-10m-PUR 902-51766
Содержание FA 46 301-CR
Страница 49: ......