FA 46 Vision Sensor GB - 068-14297 - 10.02.2011-05
Mounting and
operating instructions
56
3
Installation Instructions
3.1
Mechanical Installation
To ensure maximum accuracy of detection, the FA 46 Vision Sensor should be protected from
vibration.
Secure the connection cables with cable binders to prevent crushing or slipping.
Select a position for the FA 46 Vision Sensor in which interfering factors such as slight
differences in the position of the object or variations in illumination have little or no effect.
Screw the FA 46 Vision Sensor onto the mounting clamp „dovetail FA 46“ (supplied with the unit) and then onto a
suitable object. Use only the mounting clamp „dovetail FA 46“ (no. 543-11000) supplied with the unit (see chapter
8.11 dimensional drawing).
Observe the object clearance given in the table Field of View / Working Distance (see chapter 8.4).
To avoid interfering reflection from the detection object, align the FA 46 Vision Sensor at an angle of approx. 10°-15°
with reference to the optical axis (fig. 1).
Fine adjustment
Important: Fine adjustment of the FA 46 Vision Sensor should not be carried out until after electrical connection (see
chapter 3.2) and start-up (PC software installation(chapter 4).
A
min.10-15°
Fig. 1
155-00231
Height of field of view
W
idth of field of view
Working distance
A
0°
Codereader
Arrangement for dark-field illumination
- for the prevention of direct reflections and
accentuation of edges etc.
Arrangement for bright-field illumination
- for transmitted light/ measuring tasks or for
the accentuation of highly-reflective objects.
Fig. 1a
155-01277
305
FA 46-305 and
FA 46-301 CR only
Connection socket
Data (RS422
301
Height of field of view
W
idth of field of view
Working distance