User Guide
Rev 2.0
www.semtech.com
23 of 27
TSDMTX-19V3-EVM
May-18
Semtech
Signal Layer
Bottom Layer
Attention:
Connect the current-sense amplifer using Kelvin connections directly to the Current sense resistor pads,
and DO NOT allow high current to flow through the Kelvin connections. It is an example for the layout.