10 MAINTENANCE MENU - DIAGNOSTICS AND ALARM MANAGEMENT
10.1 Consulting the Maintenance Menu with the Handset
•
Connect the handset to the RJ45 connector
•
If necessary, using keys
Å
and
Æ
choose the required language and confirm with the
"OK" key or confirm the suggested language with "OK"
•
Using keys Up Arrow" and
Æ
, run through the "main menu "and choose "Maintenance"
•
Press "OK" to confirm the choice
•
The following options are viewed on the display:
•
MONITOR
•
STATISTICS
•
LAST ALARMS
•
ALARMS COUNTERS
•
DISPLAY CONTRAST
•
BATTERY
•
MLC MONITOR (MAIN LIFT CONTROLLER MONITOR)
•
WARRANTLY
•
The following options are available
•
"BACK": Press key F1 to restore the menu MAINTENANCE
•
"MENU": Press key F3 to restore the MAIN MENU
•
Using keys
Å
and
Æ
, run through the menu MAINTENANCE and choose the required
option
•
Press "OK" to confirm the choice
If the option
MONITOR
is chosen, the display shows opening and closing speed profiles,
with indication of the speed in m/s.
The following options are available:
•
"Loop": Pressing key F1 the door performs a number of consequent opening and closing
cycles until key F1 is pressed again
•
"<>" or " >< ": Press key F2 to let the doors respectively open or close
•
"MENU": Press key F3 to restore the MAIN MENU
If the option
STATISTICS
is chosen , the display shows the door total working time expres-
sed in days:hours:minutes, the cycle total number which have been performed in this
working time and the manufacture date. The following options are available:
•
"BACK": Press key F1 to restore the menu MAINTENANCE
• "MENU": Press key F3 to restore the MAIN MENU
If the option
LAST ALARMS
is chosen the display shows the last occurred alarms
showing their code, the relevant description and time of occurrence (day :hour
:minute from the door controller start-up). Using keys
Å
and
Æ
, run through the sto-
red alarm list. The following options are available:
•
"BACK": Press key F1 to restore the menu MAINTENANCE
•
"CANC": Press key F2 to cancel all stored alarms
•
"MENU": Press key F3 to restore the MAIN MENU
If the option
ALARMS COUNTERS
the display views the alarm list showing their code, the
relevant description and the number of times they have occurred. Using keys
Å
and
Æ
, run
through the stored alarm list.
The following options are available:
•
"BACK": Press key F1 to restore the menu MAINTENANCE
•
"CANC": Press key F2 to cancel all stored alarms
•
"MENU": Press key F3 to restore the MAIN MENU
The viewed alarms are the same as in the Alarms Table in § 6.14.