background image

   

pg. 3 

   

Introduction

 

Safety and Compliance 

 

This document provides instructions to install the ChargePro™ 620 Charging Station and should not be 
used for any other product. This product must be installed in accordance with the National Electrical Code 
(NEC), the Canadian Electrical Code (CEC) or any applicable local code.  
 
Review this manual and consult a licensed contractor and/or electrician before installation to ensure 
compliance with local building practices, climate conditions, safety standards, and state and local codes.  
 
The ChargePro™ 620 Charging Station should be installed by a licensed contractor/ electrician and 
inspected by a qualified installer prior to initial use. Under no circumstances will compliance with the 
information in this manual relieve the user of responsibility to comply with all applicable codes and safety 
standards.  
 
This document describes the most common installation and mounting methods. Contact SemaConnect 
where it is not possible to perform an installation using the procedures provided in this document, 
 
SemaConnect is not responsible for damages that may occur or result from installations that are not 
described in this document. 

 
General 

 

The ChargePro™ 620 Charging Station is grounded through a dedicated conductor to the ground 
connection at the power distribution panel. 

   

This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to 
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 
interference when the equipment is operated in a commercial environment. This equipment generates, 
uses, and can radiate radio frequency energy. This equipment may cause harmful interference with radio 
communications if not installed and used in accordance with the manufacturer’s instructions.  
 
Any Changes or modifications to this product not authorized by SemaConnect, Inc., could affect FCC 
compliance and revoke your authority to operate this product. 
 
The power output of the radiating components in this device is below the FCC radio frequency exposure 
limits for uncontrolled equipment.

  

   

Statements 

 

Reasonable effort has been made to ensure that the specifications and other information in this manual are 
accurate and complete at the time publication. However, specifications and other information in this manual 
are subject to change at any time without prior notice. 

   

Use of  the ChargePro™ 620 Charging Station in a manner not intended or any modification not approved 
by the manufacturer will void the limited warranty. Other than the limited warranty, SemaConnect products 
are provided “AS IS,” and SemaConnect and its distributors expressly disclaim all implied warranties, 
including any warranty of design, merchantability, and fitness for a particular purposes and non-
infringement, to the maximum extent permitted by law. 

   

IN NO EVENT SHALL SEMACONNECT, INC. OR ITS AUTHORIZED DISTRIBUTORS BE LIABLE FOR 
ANY INDIRECT, INCIDENTAL, SPECIAL, PUNITIVE, OR CONSEQUENTIAL DAMAGES, INCLUDING 
WITHOUT LIMITATION, LOST PROFITS, LOST DATA, LOSS OF USE, COST OF COVER, OR LOSS OR 
DAMAGE TO THE CHARGEPRO™ 620 CHARGING STATION ARISING OUT OF OR RELATING TO 
THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF SEMACONNECT, INC. OR ITS AUTHORIZED 
DISTRIBUTORS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. 

Содержание ChargePro 620

Страница 1: ...emarks service marks registered trademarks or registered service marks of their respective owners Copyright 2010 SemaConnect Inc All rights reserved This material is protected by the copyright laws of...

Страница 2: ...Instructions 15 1 Check Boxes for Correct Content 15 2 Pre Installation Preparation 15 3 Install Wall Pole Mount Bracket 17 4 Attach Cable Rack 18 5 Install the Charging Station Head Unit 18 6 Cleanin...

Страница 3: ...t is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy This equipment may cause harmful interference with radio communications if not installed...

Страница 4: ...on via SMS or email owner configured Codes and Standards Compliance Listed to UL2231 1 2 and UL2594 NEC Article 625 compliant Network Specs Local Area Network 2 4GHz 802 15 4 dynamic mesh network Wide...

Страница 5: ...ing the installation site carefully review the following Wiring color code Page 6 ChargePro 620 Charging Station technical specifications Page 4 Wiring diagrams Page 6 Wall Pole Mounting Template incl...

Страница 6: ...his document reflect Level 2 wiring color code Strictly adhere to the wire color codes to ensure proper installation Use 10 AWG wire minimum ensure compliance with electrical codes COLOR CODE BLACK RE...

Страница 7: ...lation Materials Provided ChargePro 620 Charging Station Head Unit ChargePro 620 Charging Station Pedestal Unit Cable Rack and 4 Cable Rack mounting screws Charging Station Anchor Plate 4 Anchor Bolts...

Страница 8: ...on The Anchor Plate is 18 inches in height therefore it is recommended that the concrete pad is at least 24 inches in depth check local codes In preparation for the concrete pad excavate to a depth of...

Страница 9: ...e base plate is parallel to the ground Allow sufficient time for the concrete to set before going to the next step 3 Install the Pedestal Unit Insert the Pedestal Now you are ready to install the Pede...

Страница 10: ...leveling screws that can be found on four sides are used to adjust for plumb Ensure Pedestal is Plumb Adjust leveling screws to make pedestal plumb check with Level at two points separated by 90 degr...

Страница 11: ...er tightening screws check that the Cable Rack is secure and is firmly attached to the Head Unit 5 Install Charging Station Head Unit Mount the Charging Station Head Unit Carefully insert the charging...

Страница 12: ...harging Station Head Unit for Level 2 charging stations the color codes are Red Black and Green and 3 wires from the Pedestal with the same color combination Remove the insulation on each wire and pre...

Страница 13: ...ly from the top and use a wet dry cloth to clean all the sides Never use strong detergents or any other chemicals Acids petrol thinner or any other solvent Do not exert too much of pressure on the dev...

Страница 14: ...t Installation Materials Provided ChargePro 620 Charging Station Head Unit Cable Rack and Cable Rack mounting screws Wall Pole Mount Bracket Plate Wall Mount Template Wall Pole Mount Bracket Post 4 He...

Страница 15: ...damage suggested min 3 ft Two alternatives are illustrated below Preparing the Wall At the selected location place the wall mount template on the wall such that the top of the template is at a height...

Страница 16: ...for material Now run conduit up to wire wall hole location previously marked on the wall Run the wires through this conduit up to wire wall hole location with at least 18 wall thickness free wire See...

Страница 17: ...racket Post using the Wall Pole Mount Post screws 3ea Make sure that the Post is securely attached to the Wall Mount Plate Mount the Bracket on the Bolts Now hang the Wall Pole Mount Bracket on the an...

Страница 18: ...insert the Charging Station Head Unit on top of the Wall Mount Bracket Post as shown in the diagram Align the access panel on the Charging Station Head Unit with the panel on the Wall Pole Mount Brack...

Страница 19: ...panel cover using the screws previously removed Caution Refer to the wire color codes Page 6 and strictly adhere to this convention while connecting the charging station and electrical supply wires In...

Страница 20: ...t Installation Materials Provided ChargePro 620 Charging Station Head Unit Cable Rack and Cable Rack mounting screws Wall Pole Mount Bracket Plate Wall Mount Template Wall Pole Mount Bracket Post 4 He...

Страница 21: ...he Wall Pole Mount Bracket Post for the wires Prepare the Pole 1 On the selected pole cut 1 inch diameter hole 30 inches from the ground level Check local codes 2 Run the wires from the distribution p...

Страница 22: ...3ea Make sure that the Post is securely attached to the Wall Pole Mount Plate Strap the Bracket to the Pole Now place the Wall Pole Mount Bracket against the pole and secure it with at least 3 straps...

Страница 23: ...ation Carefully insert the Charging Station Head Unit on top of the Wall Mount Bracket Post as shown in the diagram Align the access panel on the Charging Station Head Unit with the panel on the Wall...

Страница 24: ...panel cover using the screws previously removed Caution Refer to the wire color codes Page 6 and strictly adhere to this convention while connecting the charging station and electrical supply wires In...

Страница 25: ...pg 25 Appendix A Wall Mount Bracket Dimension...

Страница 26: ...pg 26 Appendix B Front View Pedestal Mount Dimensions...

Страница 27: ...pg 27 Appendix C Side View Bollard Mount Dimensions...

Отзывы: