![Selve iveo WS/WSRF Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/selve/iveo-ws-wsrf/iveo-ws-wsrf_operating-instruction_1237244018.webp)
18
GB
19
Views onto the device/Scope of delivery
Setting the sun and wind threshold values
The values can be set with the i-R Marki Send WS and the i-R Marki Send Plus. Please
refer to these operating instructions for the setting.
Rain sensor (only iveo Sensor WSRF)
The awning automatically retracts when it starts to rain. Automatic extension is pre-
vented.
Transmission control light
A radio signal is indicated by the transmission control light being lit.
Change-over switch awning/venetian blind
The control output of the sensor can be set to awning mode (bottom)/venetian blind
mode (top) via coding switch 1.
Toggle button
Use these buttons to operate the system from the sensor (e.g. testing of the transmis-
sion path).
Programming button
Use this button to program the sensor into the receiver.
4. Scope of delivery
The cardboard packaging includes the following parts:
• 1 iveo Sensor WS/WSRF
• 1 operating instruction
• 3 fixing screws DIN 7981 – Ø 4.2 x 50 mm (Torx 20) and expansion anchor S8
Required tools:
• Screwdriver Torx T10 (power supply covering), it is recommended: with torque control
• Screwdriver Torx T20 (fixing screws) and drill Ø 8 mm (for expansion anchors S8)
• Screwdriver, 3 mm (electrical terminals)