Maintenance section
User and service manual
– TOP EX – Continuous tempering machine
36
6.5.4 Replacement of the reducer
If the reducer were to malfunction replace it as follows:
1) Empty the machine as described in section
6.4.
2) Wait for the product to cool down
3) Remove the fixed protective panels as
described in section 6.5.1
4) Disconnect the motor as described in section
6.6.1
5) Remove the screws holding the electric motor
to the reducer
6) Detach the motor from the reducer and place it
on the floor. Take care not to lose the small
key located on the motor drive shaft
7) Free the low speed shaft inside the machine
by removing the blocking mechanism located
below the reducer
8) Proceeding with caution, remove the screws
holding the reducer to the machine and place
it on the ground
9) Install the new reducer taking care to correctly
position the central shaft
10) Re-attach the reducer to the machine by using
the screws
11) Re-instate the blocking mechanism of the low
speed shaft
12) Insert the motor shaft into the reducer taking
care to correctly reposition the small key
13) Attach the motor to the reducer via the screws
14) Put the fixed protective panels back in place
6.5.5 Replacing the motor
To replace the motor act as follows:
1) Disconnect the motor as described in section
6.6.1
2) Remove the screws that attach the motor to
the reducer
3) Detach the motor from the reducer, taking care
not to lose the small key present on the motor
shaft, and place it on the ground
4) Insert the shaft of the new motor into the
reducer taking care to correctly reposition the
small key
5) Attach the motor to the reducer via the screws
6) Reconnect the motor as described in section
6.6.1
7) Put the fixed protective panels back in place
6.6. Maintenance of electrical system
Attention
Before
taking
any
action
on
electrical
components disconnect the machine from the
mains.
Always carefully check the isolating covers, the clamps
and the grip of the sheaths;
seal gaskets
cannot
guarantee the IP level of protection declared by the
manufacturer if they are not correctly positioned or if
they are damaged.
Replace sheaths and cables if their isolating covers are
ruined or damaged.
Check and restore, if necessary, the identification
labels and stickers of the wires and of the components
keeping to the indications shown in the electrical
diagrams.
Make sure that the identification plate of the electric
panel (see section 1.9) and the adhesive electric
hazard plaque (see section 2.3) are perfectly legible
and firmly attached; otherwise replace them by
requesting new ones from the manufacturer.
The replacement of faulty control components must
always be carried out according to the norms in force,
using components with technical characteristics
complying with those of the components that need to
be replaced.
Use exclusively original SELMI spare
parts. The manufacturer will take no
responsibility for accidents or damages in
the case o fuse of non-original spare parts.
Содержание TOP EX
Страница 1: ...TOP EX User and service manual Page not to be printed...
Страница 43: ...Maintenance section User and service manual TOP EX Continuous tempering machine 41...
Страница 44: ...Maintenance section User and service manual TOP EX Continuous tempering machine 42...
Страница 45: ...Maintenance section User and service manual TOP EX Continuous tempering machine 43...
Страница 46: ...Maintenance section User and service manual TOP EX Continuous tempering machine 44...
Страница 47: ...Maintenance section User and service manual TOP EX Continuous tempering machine 45...
Страница 48: ...Maintenance section User and service manual TOP EX Continuous tempering machine 46...
Страница 49: ...Maintenance section User and service manual TOP EX Continuous tempering machine 47...
Страница 50: ...Maintenance section User and service manual TOP EX Continuous tempering machine 48...