![SELMI TANK 200 Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/selmi/tank-200/tank-200_user-and-service-manual_1237110037.webp)
TANK
33
6.6. Maintenance of electrical system
Attention
Before taking any action on electrical
components disconnect the machine from the
mains.
Always carefully check the isolating covers, the
clamps and the grip of the sheaths;
seal gaskets
cannot guarantee the IP level of protection declared
by the manufacturer if they are not correctly
positioned or if they are damaged.
Replace sheaths and cables if their isolating covers
are ruined or damaged.
Check and restore, if necessary, the identification
labels and stickers of the wires and of the
components keeping to the indications shown in the
electrical diagrams.
Make sure that the identification plate of the electric
panel (see section 1.9) and the adhesive electric
hazard plaque (see section 2.3) are perfectly legible
and firmly attached; otherwise replace them by
requesting new ones from the manufacturer.
The replacement of faulty control components must
always be carried out according to the norms in
force,
using
components
with
technical
characteristics complying with those of the
components that need to be replaced.
Use exclusively original SELMI spare
parts
The
manufacturer
will
take
no
responsibility for accidents or damages
in the case o fuse of non-original spare
parts.
6.6.1 Disconnection and reconnection of the motor
If the motor needs to be replaced an electrical
technician will need to intervene. He will firstly have
to disconnect the damaged motor and then connect
the new motor.
Follow these steps to disconnect the motor:
1) Remove the lateral fixed protective panels
following the instructions given in section
6.5.1
2) Remove the screws of the connection
terminal protective box
3) Disconnect the wires paying attention to the
terminal each wire is connected to. You will
need to remember this when you come to
reconnect the wires
4) Free the cable from the cable holder that
holds it to the motor and pull it out
Attention
Never connect the power supply when one or
more of the electrical components of the
machine are disconnected and the conductors
are not correctly isolated.
To connect the new motor follow these steps:
1) Make sure that the electrical characteristics
of the new motor are compatible with the
original one’s
2) Unscrew the protective box of the
connection terminal
3) Reinstate the motor power cable into the
appropriate cable holder
4) Tighten the cable holder until it has a good
grip of the cable, paying attention not to use
too much force, as there is danger of
damaging the cable or the cable holder
5) Reconnect the wires into the connection
terminal
6) Remount the protective box of the
connection terminal and fix it in place with
the screws.
Содержание TANK 200
Страница 1: ...A...
Страница 2: ...B...
Страница 40: ...TANK 36 7 TECHNICAL DIAGRAMS 7 1 Technical diagrams...
Страница 41: ...TANK 37...
Страница 42: ...TANK 38...
Страница 43: ...TANK 39...
Страница 44: ...TANK 40...
Страница 45: ...TANK 41...
Страница 46: ...TANK 42...
Страница 47: ...TANK 43...
Страница 48: ...TANK 44...
Страница 49: ...TANK 45...
Страница 50: ...TANK 46...
Страница 51: ...TANK 47...