SmartBox
®
MINI
21 / 36
Menu step
Entry function
Entry value
Tank shape
Choice of tank shape
Linear
linear
tank; rectangular tank; vertical cylinder; steel tank
welded together in the basement
Cylinder
cylindrical
tank to 50 m³ (see also alternative
Cyl. > 50000 L) horizontal cylinder; tube-shaped tank;
typical design as outdoor tank or underground steel tank
Ball
spherical
tank
underground, spherical tank; often a plastic (GRP)
underground tank
Oval
oval
tank in basement
typical design of GRP tanks and single-walled sheet
metal tanks
Convex
plastic battery tank,
convex
slightly convex shape, alternative to linear
Concave
plastic battery tank,
concave
slightly concave shape, alternative to linear
Cylinder
> 50000 L
cylindrical
large outdoor tank ˃50 m³; ˃50000 L to
100000 L
Steel Tank
Sheet steel tank or tank battery
Straight side walls with semicircular dome at top and
bottom
Display Type
Set the display
OnTouch
Select a setting and confirm with [Enter].
Ok is displayed. Value is displayed for a short time.
Sleep mode
Permanent
Select a setting and confirm with [Enter].
Ok is displayed. Continuous display
Continuous
display, sensor
not in operation
Exit
Programming completed
Display type "Permanent" is recommended only for short times during battery operation.
After programming, the digital display is ready for
"Set Null"
, the zero offset adjustment with
the FSA-E.