SmartBox
®
MINI
20 / 36
You can enter the parameters before the "Set Null" zero offset adjustment between the digital
display unit and the FSA-E or also after "Set Null".
Factory settings
Menu item
Default parameters
Unit
Litre
Sensor Type
250 cm FSA-E
maximum Height
250 cm
maximum Volume
2500 L
Tank shape
Linear
Display Type
OnTouch
Menu item
Entry function
Entry value
Unit
Choice of display unit
Litre
Select a setting and confirm with [Enter].
Ok is displayed.
Display in litres
Percent
Display volume in %
Height
Display level in cm
Set Null
Zero offset adjustment between the digital
display unit and the FSA-E
Adjustment with "Set
Null"
Sensor Type
Enter the measuring range
250 cm FSA-E
Select a setting and confirm with [Enter].
Ok is displayed.
0 - 250
160 cm FSA-E
0 - 160
maximum
Height
Enter the maximum internal height of the
tank
(height without dome)
250 cm FSA-E
Enter with (+)/(-) and press [Enter] to confirm.
Ok is displayed.
Max H ≤ 240 cm
160 cm FSA-E
Max H ≤ 150 cm
maximum
Volume
Enter the tank volume
Enter with (+)/(-) and press [Enter] to confirm.
Ok is displayed.
Max V ≤ 999999 L
If the selection of the sensor type changes, you have to re-enter this and the maximum tank
height.