SmartBox
®
MINI
17 / 36
CONNECTIONS
Connecting the cable to the digital display unit
With the power disconnected, remove the top of the housing to connect the cable
.
Connect the cable to the digital display unit:
•
Carefully pierce the white membrane to feed the cable through.
•
Insert the connection cable through the cable opening on the bottom part of the housing.
•
Connect the coloured cable cores according to the terminal assignment.
Terminal assignment from left to right:
1
ws = White
2
bn = Brown
3
gn = Green
4
gb = Yellow
5
gr = Grey
Connecting the cable:
•
Depress the spring clamp with a suitable screwdriver.
•
Insert the coloured cable cores into the openings of the terminal block.
•
Release the spring clamp.
•
Check that the connection is firm. Assemble the cable relief.
•
Position the clip-on ferrite core near the housing.
•
Insert the batteries in the battery compartment of the digital display unit.
Malfunction if cable is touched when live.
Permanent damage to the digital display unit cannot be ruled out.
Insert the batteries
only after
you have connected the cable.
Malfunction as a result of incorrect wiring.
The proper function is no longer guaranteed.
Check the terminal assignment.
Cable extension/wall duct options
Recommended cable extension with a LIYY cable, cable cross-section
5 x 0.25 mm
2
; cable diameter 4.5 to 6 mm (up to 50 m extension possible).
Extend the connection cable and/or pass through a wall:
•
Remove the clip-on ferrite core from the cable.
•
Extend the connection cable or pass it through a wall:
•
Replace the clip-on ferrite core on the cable.
•
Connect the cable to the digital display unit
(see above).
•